CRANE NAVAL DEPOT, IN —
OSHA Inspection: US DEPARTMENT OF DEFENSE, DEFENSE LOGISTICS AGENCY, NAVAL SUPPORT ACTIVITY, CRANE, IN
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of US DEPARTMENT OF DEFENSE, DEFENSE LOGISTICS AGENCY, NAVAL SUPPORT ACTIVITY, CRANE, IN in BUILDING 41, HIGHWAY 300 361, CRANE NAVAL DEPOT, IN 47522 (NAICS 493110). OSHA activity number 340438811.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- BUILDING 41, HIGHWAY 300 361
- City
- CRANE NAVAL DEPOT
- State
- IN
- ZIP
- 47522
- Mailing
- 300 HIGHWAY 361, BUILDING 41, CRANE, IN 47522
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 75
- Ownership type
- D
Citations
4 citations on file for this inspection.
1910.22 B01
- Issued
- Mar 19, 2015
- Abate by
- Apr 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(b)(1): Where mechanical handling equipment is used, sufficient safe clearances shall be allowed for aisles, at loading docks, through doorways and wherever turns or passage must be made. Aisles and passageways shall be kept clear and in good repairs, with no obstruction across or in aisles that could create a hazard. a) On or about March 5, 2015, in the hazardous material storage area located in Building 479, the entrance door metal threshold was broken and protruding upwards resulting in an obstruction across the doorway. Employees were exposed to slip/trip hazards which could result in cuts, scrapes, abrasions and broken bones.
Recent events (1)
- — Z (S) $0
1910.26 C02 VII
- Issued
- Mar 19, 2015
- Abate by
- Mar 31, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.26(c)(2)(vii): Ladders having defects are to be marked and taken out of service until repaired by either maintenance department or the manufacturer. a) On or about March 5, 2015, in Building 41 at column 31e, a metal platform ladder was defective in that the bottom support rail was bent and was not taken out of service. Employees were exposed to a fall hazard which could result in fractures, broken bones and possible death.
Recent events (1)
- — Z (S) $0
1910.213 H04
- Issued
- Mar 19, 2015
- Abate by
- Mar 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(h)(4): Radial Saws: Installation shall be in such a manner that the front end of the unit will be slightly higher than the rear, so as to cause the cutting head to return gently to the starting position when released by the operator. a) On or about March 5, 2015, in the woodworking shop located in Building 40 , the radial arm saw cutting head would not return gently to the starting position when released by the operator. Employees were exposed to cuts, scrapes and possible amputations of body parts.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Mar 19, 2015
- Abate by
- Mar 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible Cords, unless specifically permitted, may not be used: As a substitute for the fixed wiring of a structure. a) On or about March 5, 2015, at the packing station in Building 41, a flexible cord was being used as permanent wiring. Employees were exposed to electrical hazards which could results in burns, shock and possible electrocution.
Recent events (1)
- — Z (S) $0
More inspections at US Department of Defense, Defense Logistics Agency, Naval Support Activity, Crane, in
More inspections in this industry (NAICS 493110)
More inspections in IN
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340438811.