Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BMB CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BMB CONSTRUCTION in 1482 ROUTE 9, CLIFTON PARK, NY 12065 (NAICS 238130). OSHA activity number 340443449.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BMB Construction — free Get an email when a new federal OSHA severe-injury report for BMB Construction is published. One employer, no account, unsubscribe in one click.
Establishment
BMB CONSTRUCTION
Site address
1482 ROUTE 9
City
CLIFTON PARK
State
NY
ZIP
12065
Mailing
19 GENEVA BLVD., WYNANTSKILL, NY 12198
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 13, 2015
Penalty
Initial $1,700 · Current $1,700
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s)  (a) During framing work:  On or prior to 3/05/15, inspections of the jobsite, including tools and equipment, were not conducted by a competent person.    Abatement Note:  A competent person is one who is capable of recognizing existing and predictable hazards in the surroundings or working conditions which are hazardous, or dangerous to employees, and who has authorization to take prompt corrective action to eliminate them.
Recent events (1)
  • — Z (S) $1700

1926.95 A

Serious Gravity 1 1 instance 4 exposed
Issued
Mar 13, 2015
Penalty
Initial $1,020 · Current $1,020
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided:  (a)  During framing work:  On or prior to 3/5/15, protective helmets and protective eyewear were not provided for employee use during framing work, including but not limited to:  operation of framing nailers, circular saws, and related tools and equipment.
Recent events (1)
  • — Z (S) $1020

1926.404 B01 II

Serious Gravity 1 3 instances 4 exposed
Issued
Mar 13, 2015
Penalty
Initial $1,020 · Current $1,020
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection.  (a)  During framing work:  On or prior to 3/5/15, extension cord set(s) used to power equipment including, but not limited to DeWalt Circular saw(s), a DeWalt 1/2" drill, and a DeWalt sawzall, were not provided with GFCI protection.
Recent events (1)
  • — Z (S) $1020

1926.1053 B13

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 13, 2015
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step:  (a) During framing work:  On or about 3/5/15, employee was using the top step and/or top of an 8' Werner fiberglass stepladder while nailiing framing member(s) at the front of the building.
Recent events (1)
  • — Z (S) $1200

1926.403 B02

Other-than-serious 1 instance 4 exposed
Issued
Mar 13, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:   (a) During framing work:  On or about 3/05/15, a 6 outlet RPT (relocatable power tap or "power strip") was used to supply power to a small Husky air compressor and several tools, including: 2 DeWalt circular saws, a DeWalt hammer drill, and a DeWalt reciprocating saw (sawzall).
Recent events (1)
  • — Z (O) $0

View BMB Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340443449.