Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MP GLOBAL PRODUCTS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MP GLOBAL PRODUCTS, LLC in 2500 OLD HADAR RD. 2300 RIVERSIDE BLVD, NORFOLK, NE 68701 (NAICS 313110). OSHA activity number 340452317.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MP Global Products, LLC — free Get an email when a new federal OSHA severe-injury report for MP Global Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2500 OLD HADAR RD. 2300 RIVERSIDE BLVD
City
NORFOLK
State
NE
ZIP
68701
Mailing
P.O. BOX 2283, NORFOLK, NE 68701
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313110
Employees
85
Ownership type
A

21 citations on file for this inspection.

1910.22 B01

Serious Gravity 5 3 instances 5 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $5,500 · Current $7,000
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard.    The employer is failing to protect employees from emergency egress hazards associated with working in a facility with blocked or restricted aisle ways.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees using blocked or restricted aisle ways as means of access to areas where they need to work
Recent events (3)
  • — F (S) $7000
  • — C (S) $5500
  • — Z (S) $5500

1910.37 B06

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $5,500 · Current $0 Reduced
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:     The employer is failing to protect employees from emergency egress hazards associated with inadequately lighted emergency exit and exit signs.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees working in the facility where the nearest designated exit has an inadequate exit sign or lacks sufficient illumination.   Instances include but are not limited to the exit door on the east side of the main production floor next to the lamination machine.
Recent events (3)
  • — F (S) $0
  • — C (S) $5500
  • — Z (S) $5500

1910.23 C01

Serious Gravity 10 3 instances 7 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    The employer is failing to protect employees from fall hazards associated with working on platforms greater than 4 feet above the lower working surface.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees performing maintenance on equipment such as the exhaust fans located on upper work platforms where there is missing guard railing.  Instances include but are not limited to:  i.  Employees using a fixed ladder as means of access to the top of the Bema Mixer so they can look into the overhead observations door to verify the machine is not plugged up.  ii.  Employees using a fixed ladder with unprotected access point, as means of access to the catwalk along the north wall between the main production line and the dust collector room.   iii.  Employees using a fixed ladder with unprotected access point, as means of access to the work platform over the laminating line as means of conducting maintenance on the exhaust fan located there.
Recent events (3)
  • — F (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.147 C07 I A

Serious Gravity 5 2 instances 1 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $5,500 · Current $7,000
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:    The employer is failing to provide adequate lockout and tag out training to authorized employees.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees who operate and or perform maintenance on equipment that requires them to lock the machine out against hazardous energy sources through the use of lockout and tag out, they have been authorized by the company to perform lockout and/or tag out however they have not been given the required training.  Instances include but are not limited to:  i.  Employee clearing jams out of machines in the Fiber Line, Thermal Pad Line and the Main Production Lines.   ii. Employees cleaning the machines weekly where they are required to apply lockout and/or tag.
Recent events (3)
  • — F (S) $7000
  • — C (S) $5500
  • — Z (S) $5500

1910.147 C07 I B

Serious Gravity 5 2 instances 5 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure:     The employer is failing to provide adequate lockout and tag out training to affected employees.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has inadequately trained affected employees who operate equipment that requires lock out or tag out to isolate hazardous energy sources as means of protection for the employee.  Instances include but are not limited to:     i.  Employee operating machines in the Fiber Line, Thermal Pad Line and the Main Production Lines.     ii. Employees cleaning the Fiber Line, Thermal Pad Line and the Main Production Line weekly.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C08

Serious Gravity 10 2 instances 4 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(c)(8): Lockout or tagout was not performed only by the authorized employees who are performing the servicing or maintenance:    The employer is failing to protect employees from electrical and caught between hazards associated with improper application of locks in support of lockout and taq out when performing maintenance on equipment.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees using locks assigned to other employees or in some instances having employees or supervisors lock the machines out for them so as that the exposed employee does not have positive control over the applied lock.  Instances include but are not limited to:  i.  Maintenance employees having the maintenance supervisor apply his lock so the mechanics can repair the machines.    Machine operators having supervisors apply their locks and allowing the operator to clean the machine without having positive control over the applied lock
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.178 L02 II

Serious Gravity 10 2 instances 57 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.     The employer is failing to provide adequate powered industrial truck training to employees tasked to forklifts and shag trucks throughout the facility.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees operating the shag truck and multiple sit down propane powered forklifts throughout both facilities with having conducted adequate training.  Instances include but are not limited to:    i.  Employees forced to sign certification stating that they had received a hands on evaluation when in fact they had not.   ii. Employees took a written quiz where the instructor provided all the answers thus failed to conduct an accurate assessment of the employees training.
Recent events (3)
  • — F (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.178 P01

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition:    The employer is failing to protect employees from struck by and caught between hazards associated with operating powered industrial trucks with missing safety equipment.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees operating the shag truck parked along the west side of the building with a missing seat belt, as a means of moving trailers around the company property as well as drive the shag truck on the public roads to the company buildings across the highway.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 1 instance 8 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    The employer is failing to protect employees from amputation hazards associated with operating equipment with inadequate guarding.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees operating, cleaning and performing maintenance on the inadequately guarded cross cut saw located in the thermal pad line.  Instances of exposure include but are not limited to:      i.  Employer having employees clean under the machine while it is operating where the saw is not guarded.      ii.  Employer storing supplies under the cross cut saw where employees have to reach to get them and the saw is not guarded.      iii. Access panel to moving parts on the Fibrabaler secured with a hand tightening screw.     iv. Several access panel to moving parts and electrical components on the Fiber Openers on the China Line have unlockable latches as means of securing the doors.
Recent events (3)
  • — F (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $4,400 · Current $7,000
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    The employer is failing to protect employees from struck by hazards associated with operating a bench grinder when the tool rest is adjusted greater than 1/8th of an inch.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has maintenance employees using the bench grinder to sharpen tools without having properly adjusted the tool rest.
Recent events (3)
  • — F (S) $7000
  • — C (S) $4400
  • — Z (S) $4400

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    The employer is failing to protect employees from struck by hazards associated with operating a bench grinder when the tongue guard is adjusted greater than 1/4th of an inch.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has maintenance employees using the bench grinder to sharpen tools without having properly adjusted the tongue guard.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.215 D03

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.215(d)(3): The contact surface(s) of wheel(s), blotter(s) or flange(s) on grinding machine(s) were not flat and free or foreign matter:    The employer is failing to protect employees from struck by hazards associated with operating a bench grinder with an uneven surface on the grinding wheel.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has maintenance employees using the bench grinder with the rounded off grinding wheel to sharpen tools.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 3 instances 2 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $5,500 · Current $7,000
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    The employer is failing to protect employees from caught between hazards associated with inadequately guarded belt and pulley assemblies.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees operating and working the lines where there are belt and pulley assemblies with inadequate guarding.  Instances include but are not limited to:  i.  Employees working on the Fiber Openers on the China Line in the Fiber Line   ii.  Employees working on the China Machine in the Fiber Line.
Recent events (3)
  • — F (S) $7000
  • — C (S) $5500
  • — Z (S) $5500

1910.219 E03 I

Serious Gravity 5 3 instances 2 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):    The employer is failing to protect employees from caught between hazards associated with inadequately guarded belt and pulley assemblies.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees operating and working the lines where there are belt and pulley assemblies with inadequate guarding.  Instances include but are not limited to:  i.  Employees working on the Fiber Openers on the China Line in the Fiber Line   ii.  Employees working on the China Machine in the Fiber Line.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.219 F03

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $5,500 · Current $0 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven 7 feet or less above floors or platforms were not enclosed:    The employer is failing to protect employees from caught between hazards associated with inadequately guarded chain and sprocket assemblies.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees operating and working the lines where there are chain and sprocket assemblies with inadequate guarding.  Instances include but are not limited to employees working on the China Machine in the Fiber Line.
Recent events (3)
  • — F (S) $0
  • — C (S) $5500
  • — Z (S) $5500

1910.303 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $5,500 · Current $7,000
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:    The employer is failing to protect employees from electrical hazards associated with damaged electrical panel boxes in the work place.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees accessing the damaged electrical box in the Fiber Line as means of de-energizing the overhead fluorescent lights when changing the bulbs thus exposing the employee to live electrical parts.
Recent events (3)
  • — F (S) $7000
  • — C (S) $5500
  • — Z (S) $5500

1910.303 F02

Serious Gravity 5 1 instance 6 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $5,500 · Current $0 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    The employer is failing to protect employees from electrical hazards associated with inadequately labeled electrical panel boxes in the work place.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees accessing the inadequately labeled electrical box in the Thermal Pad building as means of de-energizing the overhead fluorescent lights when changing the bulbs thus exposing the employee to live electrical parts.
Recent events (3)
  • — F (S) $0
  • — C (S) $5500
  • — Z (S) $5500

1910.303 G01 II

Serious Gravity 5 3 instances 2 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $5,500 · Current $0 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:     The employer is failing to protect employees from electrical hazards associated with blocked access to electrical panel boxes in the work place.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees who access electrical panel boxes as the means of de-energizing lights and equipment and the employer has blocked the access to these electrical boxes.  Instances include but are not limited to:    i.  Three separate electrical panel boxes in the Thermal Pad Line facility having material and debris stacked in front of the box limiting access.
Recent events (3)
  • — F (S) $0
  • — C (S) $5500
  • — Z (S) $5500

1910.305 B01

Serious Gravity 5 4 instances 2 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $5,500 · Current $0 Reduced
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed:     The employer is failing to protect employees from electrical hazards associated with missing knockouts in outlet boxes and open circuit breaker slots in electrical panel boxes.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees using outlets and accessing electrical panel boxes with exposed live wiring.  Instances include but are not limited to:  i.  Employees using the outlet box with missing knockouts located next to the electrical panel box near the east exit on the Thermal Pad Line.   ii. Employees using and access the 440 volt main electrical board with missing circuit breakers or blank adapter located along the east wall of the Fiber Line.   iii. Employees using and accessing the electrical panel box located in the Break Room located near the Fiber Line with missing circuit breakers or blank adapters.   iv. Employees using and accessing the electrical panel box located in the Thermal Pad Line with missing circuit breakers or blank adapters.
Recent events (3)
  • — F (S) $0
  • — C (S) $5500
  • — Z (S) $5500

1910.212 A01

Willful Gravity 10 3 instances 3 exposed
Issued
Aug 26, 2015
Abate by
Jul 30, 2016
Penalty
Initial $70,000 · Current $70,000
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    The employer is failing to protect employees from amputation hazards associated with operating equipment with inadequate machine guarding.  This was most recently evident during the inspection of the facilities located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE; where the employer has exposed employees to inadequately guarded machines in the following instances:    a. Employer has employees opening observation door on the Bermatic Fiber Opener machine to clear jams resulting in employee being injured by moving parts.  b. Employer has employees operating the two automated fold and sew machines located on the Thermal Pod without proper or adequate guarding.  c. Employer has maintenance employee using the drill press located in the maintenance of the main facility without proper or adequate guarding.  d. Employer has employees feeding padding into the upper laminator on the main line without providing proper or adequate guarding.
Recent events (3)
  • — F (W) $70000
  • — C (W) $70000
  • — Z (W) $70000

1910.212 A03 II

Deleted Willful Gravity 10 3 instances 14 exposed
Issued
Aug 26, 2015
Abate by
Sep 10, 2015
Penalty
Initial $70,000 · Current $0 Reduced
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:   The employer is failing to protect employees from amputation hazards associated with operating equipment with inadequate point of operating guarding.  This was most recently evident during the inspection of the facility located at 2500 Old Hadar Rd & 2300 Riverside Blvd. Norfolk, NE 68701; where the employer has employees operating equipment with inadequate or missing point of operation guarding.  Instances include but are not limited to: i.  Employees operating the two automated fold and sew machines located in the Thermal Pad Line. ii.  Maintenance employees using the drill press located in the maintenance shop of the main facility.
Recent events (3)
  • — F (W) $0
  • — C (W) $70000
  • — Z (W) $70000

View MP Global Products, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340452317.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.