AUSTIN, TX —
OSHA Inspection: HANSON PIPE & PRECAST
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of HANSON PIPE & PRECAST in 801 AIRPORT BLVD, AUSTIN, TX 78702 (NAICS 327332). OSHA activity number 340458736.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HANSON PIPE & PRECAST
- Site address
- 801 AIRPORT BLVD
- City
- AUSTIN
- State
- TX
- ZIP
- 78702
- Mailing
- 801 AIRPORT BLVD, AUSTIN, TX 78702
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327332
- Employees
- 45
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.29 A04 II
- Issued
- Jun 3, 2015
- Abate by
- Jun 17, 2015
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.29(a)(4)(ii): All scaffold casters were not provided with a positive wheel and/or swivel lock to prevent movement. On or about 9 March 2015, the employer did not provide a means for locking the wheels of five (5) job fabricated, manually-propelled mobile ladders during use, exposing employees to a fall hazard.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.253 B04 III
- Issued
- Jun 3, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. On or about 9 March 2015, the oxygen cylinders and acetylene cylinders were stored without a 20 foot separation or a fire resistance barrier, exposing employees working in the area to a fire or explosion hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 E01
- Issued
- Jun 3, 2015
- Abate by
- Jun 17, 2015
- Penalty
- Initial $500 · Current $300 Reduced
General-duty citation text
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed so as to prevent moisture or water from entering and accumulating within the enclosures. On or about 9 March 2015, water from a roof leak was dripping onto an electrical socket that was not rated for moist environments. Although it had a GFCI, it did not have barriers for preventing moisture from entering into the socket exposing employees to an electrical shock hazard.
Recent events (2)
- — I (O) $300
- — Z (O) $500
More inspections at Hanson Pipe & Precast
View Hanson Pipe & Precast's full OSHA safety record →
More inspections in this industry (NAICS 327332)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340458736.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.