FAIRMONT, WV —
OSHA Inspection: MOUNTAINEER CABINET COMPANY, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of MOUNTAINEER CABINET COMPANY, INC. in 1917 LOCUST AVENUE, FAIRMONT, WV 26554 (NAICS 337110). OSHA activity number 340460385.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOUNTAINEER CABINET COMPANY, INC.
- Site address
- 1917 LOCUST AVENUE
- City
- FAIRMONT
- State
- WV
- ZIP
- 26554
- Mailing
- 1917 LOCUST AVENUE, FAIRMONT, WV 26554
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 40
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.107 G02
- Issued
- Jun 10, 2015
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material: (a) Finishing Area: Employees conducts spray painting of wooden cabinet components inside a ventilated spray booth. The interior sides of the spray booth were deposited with combustible overspray on the walls, as determined on March 10, 2015.
Recent events (1)
- — Z (S) $2100
1910.212 A01
- Issued
- Jun 10, 2015
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Old Door Shop: The employer did not ensure that machine guarding was provided on a HDC Tools drill press (serial #1009159, model #FDM-16) to protect employees from the rotating chuck and the unused portion of the bit, as determined on March 10, 2015.
Recent events (1)
- — Z (S) $2100
1910.213 H03
- Issued
- Jun 10, 2015
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.213(h)(3): Radial saw(s) were not provided with an adjustable stop to prevent the forward travel of the blade beyond the position necessary to complete the cut in repetitive operations: (a) Rough Mill: Employees operate a DeWalt 7790 12 inch radial arm saw to cut wooden cabinet components. The bottom portion of the blade of the radial arm saw could be extended up to 4 inches past the cutting table in forward traveling position, as determined on March 10, 2015.
Recent events (1)
- — Z (S) $2100
1910.1048 D03 II
- Issued
- Jun 10, 2015
- Abate by
- Nov 15, 2015
- Penalty
- Initial $200 · Current $200
1291
General-duty citation text
29 CFR 1910.1048(d)(3)(ii): When the last monitoring results for formaldehyde revealed employee exposure at or above the action level, monitoring of employees was not repeated at least every 6 months: (a) Finishing Area: The employer did not conduct employee exposure formaldehyde monitoring at least every six months after monitoring conducted on October 22, 2010 and November 8, 2013 indicated that employee exposure was above the action level, as determined on March 10, 2015. Abatement Documentation and Certification Required for this Item. The Mountaineer Cabinet Company, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1048(d)(3)(ii), which was contained in OSHA inspection number 313371411, citation number 1, item number 7 and was affirmed as a final order on April 22, 2010, with respect to a workplace located at 1917 Locust Avenue, Fairmont, WV 26554.
Recent events (1)
- — Z (R) $200
1910.1048 L01 I
- Issued
- Jun 10, 2015
- Abate by
- Sep 1, 2015
- Penalty
- Initial $200 · Current $200
1291
General-duty citation text
29 CFR 1910.1048(l)(1)(i): The employer did not institute medical surveillance programs for all employees exposed to formaldehyde at concentrations at or exceeding the action level or exceeding the STEL: (a) Finishing Area: An employee was exposed to an 8-hour time weighted average of 0.592 ppm of formaldehyde during a 451 minutes sampling time conducted on April 29, 2015 during the application of paint and primer on manufactured cabinets. The employer did not institute a medical surveillance program for employees exposed above the action level of 0.50 ppm, as determined on May 11, 2015. Abatement Documentation and Certification Required for this Item. The Mountaineer Cabinet Company, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1048(l)(1)(i), which was contained in OSHA inspection number 313371411, citation number 1, item number 8 and was affirmed as a final order on April 22, 2010, with respect to a workplace located at 1917 Locust Avenue, Fairmont, WV 26554.
Recent events (1)
- — Z (R) $200
1910.1048 N01
- Issued
- Jun 10, 2015
- Abate by
- Jul 28, 2015
- Penalty
- Initial $200 · Current $200
1291
General-duty citation text
29 CFR 1910.1048(n)(1): The employer did not ensure that all employees who were assigned to workplaces where there was exposure to formaldehyde participated in a training program: (a) Finishing Area: An employee was exposed to an 8-hour time weighted average of 0.592 ppm of formaldehyde during a 451 minutes sampling time conducted on April 29, 2015 during the application of paint and primer on manufactured cabinets. The employer did not ensure that all employees exposed participated in a formaldehyde training program, as determined on May 11, 2015. Abatement Documentation and Certification Required for this Item. The Mountaineer Cabinet Company, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1048(n)(1), which was contained in OSHA inspection number 313371411, citation number 1, item number 9a and was affirmed as a final order on April 22, 2010, with respect to a workplace located at 1917 Locust Avenue, Fairmont, WV 26554.
Recent events (1)
- — Z (R) $200
More inspections at Mountaineer Cabinet Company, INC.
View Mountaineer Cabinet Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340460385.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.