ATTICA, NY —
OSHA Inspection: BRETON CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BRETON CONSTRUCTION INC. in 59 MARKET STREET, ATTICA, NY 14011 (NAICS 236220). OSHA activity number 340460591.
Where did this inspection happen?
- Establishment
- BRETON CONSTRUCTION INC.
- Site address
- 59 MARKET STREET
- City
- ATTICA
- State
- NY
- ZIP
- 14011
- Mailing
- P.O. BOX 81, ATTICA, NY 14011
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.404 B01 I
- Issued
- Penalty
- Initial $1200.00 · Current $760.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) On or about 3/10/15 at a rehabilitation project located at 45 Market Street, Attica, New York; employees were using extension cords throughout the project for power to portable tools. There were no ground fault circuit interrupters in use and there was no assured equipment grounding conductor program in place. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $760
- — Z (S) $1200
1926.404 F06
- Issued
- Penalty
- Initial $1200.00 · Current $760.00 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about 3/10/15 at a rehabilitation project located at 45 Market Street, Attica, New York; an extension cord plugged in on the first floor was used to distribute power to tools on the second floor. The first floor cord was missing the ground prong. b) On or about 3/10/15 at a rehabilitation project located at 45 Market Street, Attica, New York; an extension cord used to power a Jobmax multi tool in front of the building was missing the ground prong. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $760
- — Z (S) $1200
1926.416 E01
- Issued
- Penalty
- Initial $1200.00 · Current $760.00 Reduced
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) On or about 3/10/15 at a rehabilitation project located at 45 Market Street, Attica, New York; on the second floor an extension cord used for portable power tools had the molded end pulled from the jacket exposing the conductors. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $760
- — Z (S) $1200
1926.453 B02 V
- Issued
- Penalty
- Initial $1600.00 · Current $760.00 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): 29 CFR 1926.453(b)(2)(v): A safety harness with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a) On or about 3/10/15 at a rehabilitation project located at 45 Market Street, Attica, New York; an was employee using a boom lift to repair and rehabilitate the front of the building. The employee's safety harness was not connected to the attachment point. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $760
- — Z (S) $1600
1926.1052 C01 I
- Issued
- Penalty
- Initial $1200.00 · Current $760.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) On or about 3/10/15 at a rehabilitation project located at 45 Market Street, Attica, New York; the stairway used for primary access from the first to the second floor did not have a handrail. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $760
- — Z (S) $1200
More inspections at BRETON CONSTRUCTION INC.
SPRINGVILLE, NY—2013-04-15 00:00:00
BRETON CONSTRUCTION INC.
BATAVIA, NY—2011-10-13 00:00:00
BRETON CONSTRUCTION INC.
View BRETON CONSTRUCTION INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
SIOUX FALLS, SD—2026-07-13
REM CONSTRUCTION SERVICES, LLC
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
SIOUX FALLS, SD—2026-07-10
HENRY CARLSON COMPANY
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source