Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DORMAN PRODUCTS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DORMAN PRODUCTS, INC. in 3400 E. WALNUT ST., COLMAR, PA 18915 (NAICS 336399). OSHA activity number 340460930.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dorman Products, INC. — free Get an email when a new federal OSHA severe-injury report for Dorman Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3400 E. WALNUT ST.
City
COLMAR
State
PA
ZIP
18915
Mailing
3400 E. WALNUT ST., COLMAR, PA 18915
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
700
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 640 exposed
Issued
Apr 21, 2015
Penalty
Initial $3,400 · Current $2,380 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) Production Workshop Area: On or about March 10, 2015, employees performed machine maintenance actions which require the removal of guards on machinery with multiple energy sources, including an Alloyd Blister Machine and Big Sky Machine, but the company had not developed written lockout/tag out procedures to address these energy sources, exposing the employees to injury.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $3400

1910.219 D01

Serious Gravity 5 1 instance 640 exposed
Issued
Apr 21, 2015
Penalty
Initial $2,890 · Current $2,023 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  (a) Production Work Shop Area, Engineer Lab/Shop: On or about March 10, 2015, an employee used a Jet Knee Mill machine that had an unguarded belt and pulley that was less than 7 feet above the working surface, exposing employees to potential injuries.
Recent events (2)
  • — I (S) $2023
  • — Z (S) $2890

1910.219 E01 I

Serious Gravity 5 1 instance 640 exposed
Issued
Apr 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:  (a) Production Work Shop Area, Engineer Lab/Shop: On or about March 10, 2015, an employee used a Jet Knee Mill machine that had an unguarded horizontal belt that was less than 7 feet above the working surface, exposing employees to potential injuries.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01 II

Serious Gravity 5 1 instance 640 exposed
Issued
Apr 21, 2015
Penalty
Initial $2,890 · Current $2,023 Reduced
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:    (a) Production Work Shop Area, Engineer Lab/Shop: On or about March 10, 2015, an employee used a Jet Knee Mill machine with a loosely connected junction box that was not free from recognized hazards, exposing employees to shock/electrical hazard.
Recent events (2)
  • — I (S) $2023
  • — Z (S) $2890

1910.1200 F06

Other-than-serious 1 instance 640 exposed
Issued
Apr 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6): The employer used written materials, such as signs, placards, process sheets, or batch tickets in lieu of affixing labels to individual stationary process containers that failed to identify the container(s) to which they were applicable and did not convey the information required by 29 CFR 1910.1200(f)(5):  (a) Production Work Shop Area, Engineer Lab/Shop: On or about March 10, 2015, employees used a gallon container of Kool Mist Formula 77 coolant to service parts and equipment, but the container was not labeled, tagged or marked to indicate its contents, exposing employees to safety and or health hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Dorman Products, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340460930.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.