Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DAYTON FIREPLACE SYSTEMS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DAYTON FIREPLACE SYSTEMS, INC. in 10995 COLD SPRING DR., CENTERVILLE, OH 45458 (NAICS 238170). OSHA activity number 340467695.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dayton Fireplace Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Dayton Fireplace Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10995 COLD SPRING DR.
City
CENTERVILLE
State
OH
ZIP
45458
Mailing
470 SPRINGBORO PIKE, DAYTON, OH 45449
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
12
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 30, 2015
Penalty
Initial $2,800 · Current $1,300 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.    Located on the west side of the residential structure, one employee was observed installing a roof vent on a roof while not utilizing an adequate fall protection system. Potential fall heights were measured to be 15'-7" with a roof pitch of 8/12.
Recent events (2)
  • — I (S) $1300
  • — Z (S) $2800

1926.503 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 30, 2015
Abate by
Jun 17, 2015
Penalty
Initial $2,400 · Current $1,300 Reduced
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards:     Located on the west side of the steep sloped residential roof structure an employee was observed without conventional fall protection devices or systems performing roofing associated work activities on a roof with unprotected sides or edges who was not trained or knowledgeable of the procedures or regulations to minimize those fall hazards.
Recent events (2)
  • — I (S) $1300
  • — Z (S) $2400

View Dayton Fireplace Systems, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340467695.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.