Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DAYTON FIREPLACE SYSTEMS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DAYTON FIREPLACE SYSTEMS, INC. in 1383 RICHLAND RD., XENIA, OH 45385 (NAICS 238220). OSHA activity number 344563861.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dayton Fireplace Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Dayton Fireplace Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1383 RICHLAND RD.
City
XENIA
State
OH
ZIP
45385
Mailing
1700 YANKS COURT, DAYTON, OH 45458
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
18
Ownership type
A

3 citations on file for this inspection.

1926.1053 B01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Mar 26, 2020
Penalty
Initial $5,937 · Current $0 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  a.) On or about January 16, 2020, employees were exposed to a fall hazard measured at 13 foot 3 inches while using an extension ladder to climb onto the unprotected edge of a roof surface without extending the side rails of the ladder at least 36 inches above the upper landing surface.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5937

1926.501 B13

Repeat Gravity 10 1 instance 2 exposed
Issued
Mar 26, 2020
Abate by
May 12, 2020
Penalty
Initial $11,875 · Current $5,900 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.    Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.    a.)  On or about January 16, 2020, two employees were exposed to a 13 foot 3 inch fall hazard while installing a fireplace vent cap on an 4/12 pitched residential roof and not utilizing a fall protection system.    Dayton Fireplace Systems, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1046769, citation number 1, item number 1 and was affirmed as a final order on 05/28/2015, with respect to a workplace located at 10995 Cold Spring Drive, Centerville, OH 45458.
Recent events (2)
  • — I (R) $5900
  • — Z (R) $11875

1926.503 A01

Deleted Repeat Gravity 10 1 instance 2 exposed
Issued
Mar 26, 2020
Penalty
Initial $11,875 · Current $0 Reduced
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.  a.) On or about January 16, 2020, employees were not trained to recognize fall hazards such as, but not limited to, a 13 foot 3 inch fall hazard while installing a fireplace vent cap on a pitched roof, nor were they trained on when to utilize a fall protection system.  Dayton Fireplace Systems, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.503(a)(1), which was contained in OSHA inspection number 1046769, citation number 1, item number 2 and was affirmed as a final order on 05/28/2015, with respect to a workplace located at 10995 Cold Spring Drive, Centerville, OH 45458.
Recent events (2)
  • — I (R) $0
  • — Z (R) $11875

View Dayton Fireplace Systems, INC.'s full OSHA safety record →