OSHA Inspection: AVERY DENNISON CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AVERY DENNISON CORPORATION in 170 MONARCH LANE, MIAMISBURG, OH 45342 (NAICS 561910). OSHA activity number 340468396.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Avery Dennison Corporation — free Get an email when a new federal OSHA severe-injury report for Avery Dennison Corporation is published. One employer, no account, unsubscribe in one click.
Site address
170 MONARCH LANE
City
MIAMISBURG
State
OH
ZIP
45342
Mailing
170 MONARCH LANE, MIAMISBURG, OH 45342
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561910
Employees
624
Ownership type
A

5 citations on file for this inspection.

1910.147 C05 I

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources.    (a)  On or about March 13, 2015, an employee working on the F111 Pre-Heat Oven was not provided with locks to attach to the electrical and pneumatic energy isolating devices prior to cleaning the air cylinder.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.147 D03

Serious Gravity 10 2 instances 2 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).    (a)   On or about March 13, 2015, an employee attempted to clean the air cylinder under the F111 Pre-Heat Oven, without first isolating the electric and pneumatic energy sources.      (b)  On or about March 17, 2015, employees fitted guards on the air cylinders under the F111 Pre-Heat Oven and the F112 Curing Oven, without first isolating the electric and pneumatic energy sources.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.147 D04 I

Serious Gravity 10 2 instances 2 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.    (a)   On or about March 13, 2015, an employee attempted to clean the air cylinder under the F111 Pre-Heat Oven, without first affixing a lockout device to the electrical and pneumatic energy isolating devices.      (b)  On or about March 17, 2015, employees fitted guards on the air cylinders under the F111 Pre-Heat Oven and the F112 Curing Oven, without first affixing a lockout device to the electrical and pneumatic energy isolating devices.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 10 2 instances 2 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:    (a)  There was no periodic inspection of the energy control procedures within the past year, to include a review between the inspector and each authorized employee, of that employees responsibilities under the energy control program, including observing the authorized employees actually performing servicing and/or maintenance activities on machines or equipment, such as, but not limited to, the F111 Pre-Heat Oven and the F112 Curing Oven.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.147 C07 I

Serious Gravity 10 2 instances 2 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:     (a)   On or about March 13, 2015, an employee cleaned the air cylinder under the F111 Pre-Heat Oven without first being trained on the safe application, usage and removal of energy control devices.      (b)  On or about March 17, 2015, employees placing guards on the air cylinders under the F111 Pre-Heat Oven and the F112 Curing Oven, were not adequately trained on the safe application, usage and removal of energy control devices, in that the employees did not first lock out the ovens.