Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QURE MEDICAL

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of QURE MEDICAL in 1810 RENAISSANCE BLVD., STURTEVANT, WI 53177 (NAICS 423450). OSHA activity number 340468552.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Qure Medical — free Get an email when a new federal OSHA severe-injury report for Qure Medical is published. One employer, no account, unsubscribe in one click.
Establishment
QURE MEDICAL
Site address
1810 RENAISSANCE BLVD.
City
STURTEVANT
State
WI
ZIP
53177
Mailing
1810 RENAISSANCE BLVD., STURTEVANT, WI 53177
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423450
Employees
141
Ownership type
A

5 citations on file for this inspection.

1910.38 E

Serious Gravity 1 1 instance 140 exposed
Issued
Sep 15, 2015
Abate by
Oct 9, 2015
Penalty
Initial $2,295 · Current $1,700 Reduced
29 CFR 1910.38(e):  An employer must designate and train employees to assist in a safe and orderly evacuation of other employees.    (a) The employer did not designate and train employees as required.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $2295

1910.147 C01

Serious Gravity 10 1 instance 7 exposed
Issued
Sep 15, 2015
Abate by
Nov 2, 2015
Penalty
Initial $6,300 · Current $6,300
29 CFR 1910.147(c)(1):   The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  (a) A written Hazardous Energy Control Program (Lockout/Tagout) was not developed to ensure employee(s) who perform maintenance and setup of silicone injection molding machines, rubber mills, extruders, grinders, cure ovens, and dryers were not exposed to unexpected energizing, startup or release of stored energy from mechanical equipment, heating equipment and processes associated with production operations.
Recent events (2)
  • — I (S) $6300
  • — Z (S) $6300

1910.147 C04 I

Serious Gravity 10 1 instance 7 exposed
Issued
Sep 15, 2015
Abate by
Nov 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures are not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   (a) Written machine/equipment specific energy control procedures are not developed, documented, and utilized for authorized personnel to follow when performing maintenance or servicing work on machines/equipment including but not limited to the E2 Engel 150 Injection Molding Presses, Engle Injection Molding Presses, BOY Injection Molding Presses, air compressor systems and other associated production equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.333 A

Serious Gravity 10 2 instances 7 exposed
Issued
Sep 15, 2015
Abate by
Dec 2, 2015
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:     (a) E9 Injection Molding Press: On or about March 23, 2015 a press set-up employee did not employ electrical safety related work practices when conducting continuity tests on 16 amp 480 volt AC heater fuse. Press set-up employees routinely conduct trouble shooting and repair on press electrical heaters to verify electrical fuse continuity.  Employees did not employ electrical safety-related work practices exposing employees to 480 volt AC electrical hazard.    (b) Maintenance employees routinely perform maintenance on electrical equipment, such as but not limited to lighting equipment, electrical disconnects, electrical switches, fuses and electrical control panels. Employees did not employ electrical-safety related work practices when conducting trouble shooting or verification of deenergized electrical circuits exposing employees to electrical hazards up to 480 volts AC.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6300

1910.1200 H03 IV

Other-than-serious 1 instance 140 exposed
Issued
Sep 15, 2015
Abate by
Nov 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(iv):   The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information:  (a) Employees in production operations and maintenance are exposed to but not limited to solvents, silicone rubber, oils, and grease. Training was not provided regarding the new label elements (product identifier, signal word, pictogram, hazard statement(s), and precautionary requirements) and new safety data sheet (SDS) format.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Qure Medical's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340468552.