Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STAMPCOAT, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of STAMPCOAT, INC. in 10859/10830 PELLICANO DR., EL PASO, TX 79935 (NAICS 332116). OSHA activity number 340471705.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stampcoat, INC. — free Get an email when a new federal OSHA severe-injury report for Stampcoat, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
STAMPCOAT, INC.
Site address
10859/10830 PELLICANO DR.
City
EL PASO
State
TX
ZIP
79935
Mailing
10859 PELLICANO DR., EL PASO, TX 79935
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
90
Ownership type
A

13 citations on file for this inspection.

1910.107 B05 II

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 14, 2015
Abate by
Oct 30, 2015
Penalty
Initial $3,500 · Current $2,000 Reduced
29 CFR 1910.107(b)(5)(ii): Discarded filter pads and filter rolls were not immediately removed to a safe, well-detached location or placed in a water-filled metal container and disposed of at the close of the day's operation when not maintained completely.    On March 18, 2015, and times prior to, filter pads and rolls used in Spray Booth Operations conducted in Building's #1 and #2 were not immediately removed to a safe, well-detached location or placed in water and disposed of. This condition exposed employees to fire and health hazards.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3500

1910.107 L04 I

Serious Gravity 10 2 instances 3 exposed
Issued
Sep 14, 2015
Abate by
Oct 30, 2015
Penalty
Initial $4,900 · Current $2,700 Reduced
29 CFR 1910.107(l)(4)(i): All areas were not kept free of the accumulation of powder coating dust.    On March 18, 2015, and times prior to, the Spray Room Area of Building's #1 and #2 were not kept clean and free from accumulation of powder coating material. This condition exposed employees to explosion and health hazards.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4900

1910.107 L04 II

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 14, 2015
Abate by
Oct 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.107(l)(4)(ii): Surfaces were not cleaned in such a manner as to avoid scattering dust to other places or creating dust clouds.    On March 18, 2015, and times prior to, in the Spray Booth Area of Building's #1 and #2, surfaces were not cleaned in such a manner as to avoid creating dust clouds and scattering dust to other locations. Employees were exposed to explosion and health hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 L07 II

Serious Gravity 10 2 instances 3 exposed
Issued
Sep 14, 2015
Abate by
Oct 30, 2015
Penalty
Initial $4,900 · Current $2,700 Reduced
29 CFR 1910.107(l)(7)(ii): Transformers, powerpacks, control apparatus, and all other electrical portions of the equipment, with the exception of the charging electrodes and their connections to the power supply were not located outside of the powder coating area.    On March 18, 2015, and times prior to, electrical equipment was not located outside Powder Coating Area's and exposed employees to explosion hazards in the following instances:    (a) In Building #1, the Paint Booth's Controller Box was located within the confines of the Powder Coating Area.       (b) In Building #2, the Paint Booth's Circuit Breaker was located within the confines of the Powder Coating Area.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4900

1910.107 L07 III

Serious Gravity 5 2 instances 4 exposed
Issued
Sep 14, 2015
Abate by
Oct 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.107(l)(7)(iii): All electrically conductive objects within the charging influence of the electrodes were not adequately grounded.    On March 18, 2015, and times prior to, in the Spray Room Area of Building's #1 and #2, electrically conductive objects such as metal Stools, buckets, and electrical boxes and other metal electrical equipment were not adequately grounded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 L07 IV

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 14, 2015
Abate by
Oct 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.107(l)(7)(iv): Objects being coated were not maintained in contact with the conveyor or other support in order to ensure proper grounding.    On March 18 2015, and times prior to, in the Spray Room Area of Building's #1 and #2 material being coated did not maintain contact with the conveyor or other support in order to ensure proper grounding. This condition exposed employees to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 L07 V

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 14, 2015
Abate by
Oct 16, 2015
Penalty
Initial $4,200 · Current $2,400 Reduced
29 CFR 1910.107(l)(7)(v): The electrical equipment was not interlocked with the ventilation system so that the equipment could not be operated unless the ventilation fans were in operation.    On March 18, 2015, and times prior to, electrical equipment located in the Spray Booths of Building's #1 and #2, was not interlocked with the ventilation system so that the equipment could not be operated unless the ventilation fans were in operation. This condition exposed employees to explosion and health hazards.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4200

1910.134 D01 IV

Serious Gravity 5 2 instances 4 exposed
Issued
Sep 14, 2015
Abate by
Oct 30, 2015
Penalty
Initial $4,200 · Current $2,400 Reduced
29 CFR 1910.134(d)(1)(iv): The employer did not select respirators from a sufficient number of respirator models and sizes to ensure the respirators used in the worksite were acceptable to and correctly fit the users.    On March 18, 2015, and times prior to, the employer did not select respirators from a sufficient number of respirator models and sizes to ensure respirators fit correctly and were acceptable for employees working in the Spray Room Area of Building's #1 and #2. This condition exposed employees to health hazards.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4200

1910.134 E01

Serious Gravity 5 2 instances 4 exposed
Issued
Sep 14, 2015
Abate by
Sep 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace.  On March 18, 2015, and times prior to, the employer did not have employees medically evaluated to determine the employees' ability to use a respirator before the employees were fit tested or prior to working in the Spray Room Areas of Building's #1 and #2. This condition exposed employees to health hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 5 2 instances 4 exposed
Issued
Sep 14, 2015
Abate by
Oct 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT).    On March 18, 2015, and times prior to, the employer did not ensure that employees required to use a tight-fitting face piece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) prior to working in the Spray Room Area of Building's #1 and #2. This condition exposed employees to health hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.141 A03

Serious Gravity 1 2 instances 10 exposed
Issued
Sep 14, 2015
Abate by
Oct 16, 2015
Penalty
Initial $2,100 · Current $1,200 Reduced
29 CFR 1910.141(a)(3): The employer did not ensure that all places of employment were kept clean to the extent that the nature of the work allowed.    On March 18, 2015, in the Rework Area of Building #1, Cladosporium mold was detected on the floor of the second level storage area due to a re-occurring leak from the building roof. This condition exposed employees to health hazards.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2100

1910.307 C02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 14, 2015
Abate by
Oct 16, 2015
Penalty
Initial $4,200 · Current $2,400 Reduced
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that was or could be present:    On March 18, 2015, and times prior to, electrical equipment located in the Spray Room Area of Building's #1 and #2 was not approved for the ignitable or combustible properties of powder coating residues, dust or deposits that was or could be present. This condition exposed employees to fire and explosion hazards.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4200

1910.107 L04 III

Other-than-serious 1 instance 3 exposed
Issued
Sep 14, 2015
Abate by
Sep 24, 2015
Penalty
Initial $700 · Current $0 Reduced
29 CFR 1910.107(l)(4)(iii): "No Smoking"� signs in large letters on contrasting color background were not conspicuously posted at all powder coating areas and powder storage rooms.    On March 18, 2015, and times prior to, "No smoking" signs were not posted in Powder Coating Area of Building's #1 and #2. Not posting the "No Smoking" signs allowed for a condition that could potentially expose employees to fire hazards.