Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MEI-GUAN REMODELING, INC.

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of MEI-GUAN REMODELING, INC. in 152 W. RITNER ST., PHILADELPHIA, PA 19148 (NAICS 236115). OSHA activity number 340477918.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mei-Guan Remodeling, INC. — free Get an email when a new federal OSHA severe-injury report for Mei-Guan Remodeling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
152 W. RITNER ST.
City
PHILADELPHIA
State
PA
ZIP
19148
Mailing
1353 KATER ST., PHILADELPHIA, PA 19147
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.501 B04 I

Serious Gravity 10 2 instances 2 exposed
Issued
Mar 24, 2015
Abate by
Apr 10, 2015
Penalty
Initial $2,800 · Current $1,800 Reduced
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes.       a) At 152 W. Ritner St. Philadelphia, PA 19148 - Employees working within 2 feet of the unprotected edge were exposed to a fall hazard of approximately ten (10) feet without the use of a guardrail system, a safety net system, or personal fall arrest system. Observed on or about 19 March 2015.        1- Stairs on the 1st floor.        2- Stairs on the 2nd floor.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2800

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 24, 2015
Abate by
Apr 10, 2015
Penalty
Initial $2,800 · Current $1,800 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)    a) 152 W. Ritner St., Philadelphia, PA - Employees performing stucco preparation work were exposed to fall hazards of approximately twenty (20) feet without the walking working platform of the scaffold being fully planked or decked between the front uprights and guardrail supports.  Observed on or about 19 March 2015.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2800

1926.451 E01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 24, 2015
Abate by
Apr 10, 2015
Penalty
Initial $2,800 · Current $1,800 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.     a) 152 W. Ritner St., Philadelphia, PA - Employees were not provided with a safe means of access and/or egress to the tubular welded frame scaffold platform from a lower level, exposing employees to a fall hazard of approximately twenty (20) feet.  Employees were using the side frame and crossbraces of the scaffold to access and/or egress the working levels. Observed on or about 19 March 2015.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2800

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 24, 2015
Abate by
Apr 10, 2015
Penalty
Initial $2,800 · Current $1,800 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    a) 152 W. Ritner St. Philadelphia, PA - Employees performing stucco operations from the second and third level of the tubular welded frame scaffold were exposed to fall hazards of approximately twenty (20) feet without the use of personal fall arrest or guardrail systems. Observed on or about 19 March 2015.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2800

1926.1052 C01 II

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 24, 2015
Abate by
Apr 10, 2015
Penalty
Initial $2,800 · Current $1,800 Reduced
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:    a) 152 W. Ritner St. Philadelphia, PA 19148 - The employer did not ensure that the stair rails were installed on the open sides of each stairway used by employees to access working levels thus exposing the employees to fall hazards. the stairway consisted of approximately 14 risers high per section. This condition was observed on or about 19 March 2015.        1- Stairs on 1st floor.        2- Stairs on 2nd floor.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2800

View Mei-Guan Remodeling, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340477918.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.