CROOKSVILLE, OH —
OSHA Inspection: CHRISTY CATALYTICS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CHRISTY CATALYTICS in 713 KEYSTONE STREET, CROOKSVILLE, OH 43731 (NAICS 327123). OSHA activity number 340478072.
Where did this inspection happen?
- Establishment
- CHRISTY CATALYTICS
- Site address
- 713 KEYSTONE STREET
- City
- CROOKSVILLE
- State
- OH
- ZIP
- 43731
- Mailing
- 713 KEYSTONE STREET, CROOKSVILLE, OH 43731
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327123
- Employees
- 25
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.132 D01
- Issued
- Jun 5, 2015
- Abate by
- Jul 10, 2015
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.132(d)(1): The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). a. At the site, the employer did not perform a hazard assessment of the workplace to determine if hazards were present and the need for personal protective equipment.
Recent events (1)
- — Z (S) $2100
1910.146 C01
- Issued
- Jun 5, 2015
- Abate by
- Jul 10, 2015
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1910.146(c)(1): The employer shall evaluate the workplace to determine if any spaces are permit-required confined spaces. NOTE: Proper application of the decision flow chart in Appendix A to section 1910.146 would facilitate compliance with this requirement. a. At the site, the employer did not perform an evaluation of the workplace to determine if there were any permit required confined spaces present, such as but not limited to the mixers and hopper.
Recent events (1)
- — Z (S) $3500
1910.147 C01
- Issued
- Jun 5, 2015
- Abate by
- Jul 10, 2015
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a. At the facility, the employer did not establish an energy control program for servicing and maintenance of machines and equipment, such as but limited to, the tumbler, pusher machines, clay hoppers and ball and extruder machines.
Recent events (1)
- — Z (S) $4900
1910.147 C07 I
- Issued
- Jun 5, 2015
- Abate by
- Jul 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. a. At the facility, the employer did not provide training for authorized and affected employees when machines were locked out for maintenance or repairs.
Recent events (1)
- — Z (S) $0
1910.178 A06
- Issued
- Jun 5, 2015
- Penalty
- Initial $2,100 · Current $2,100
General-duty citation text
29 CFR 1910.178(a)(6): The user shall see that all nameplates and markings are in place and are maintained in a legible condition. a. The Nissan forklift, used to move racks of material, did not have a legible name plate and markings on it.
Recent events (1)
- — Z (S) $2100
1910.178 L01 II
- Issued
- Jun 5, 2015
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1910.178(l)(1)(ii): Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5). a. At the facility, the employer did not provide training to employees before allowing them to operate forklifts to move materials and products throughout the facility.
Recent events (1)
- — Z (S) $3500
1910.212 A03 I
- Issued
- Jun 5, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.212(a)(3)(i): Point of operation is the area on a machine where work is actually performed upon the material being processed. a. In the production area, on machine 2, guards were not in place at the point of operation where the clay was extruded and cut, exposing employees to caught in hazards.
Recent events (1)
- — Z (S) $2800
1910.219 C02 I
- Issued
- Jun 5, 2015
- Abate by
- Jun 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires. a. In the production area, on machine #3, the guarding was inadequate and did not extend enough to enclose the rotating shaft that was less than seven feet from the floor.
Recent events (1)
- — Z (S) $0
1910.134 C02 I
- Issued
- Jun 5, 2015
- Abate by
- Jun 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in Appendix D to this section ("Information for Employees Using Respirators When Not Required Under the Standard"). a. At the facility, the employer did not provide Appendix D to employees that voluntarily used dust masks.
Recent events (1)
- — Z (O) $0
More inspections at Christy Catalytics
View Christy Catalytics's full OSHA safety record →
More inspections in this industry (NAICS 327123)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340478072.