Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CLEAN HARBORS

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CLEAN HARBORS in 2700 AVENUE S, SAN LEON, TX 77539 (NAICS 562211). OSHA activity number 340498203.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clean Harbors — free Get an email when a new federal OSHA severe-injury report for Clean Harbors is published. One employer, no account, unsubscribe in one click.
Establishment
CLEAN HARBORS
Site address
2700 AVENUE S
City
SAN LEON
State
TX
ZIP
77539
Mailing
2700 AVENUE S, SAN LEON, TX 77539
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562211
Employees
48
Ownership type
A

3 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 2 instances 4 exposed
Issued
Jun 15, 2015
Abate by
Jul 18, 2015
Penalty
Initial $3,750 · Current $2,675 Reduced
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet (1.22 m) or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:    a) at the facility, Thermal Oxidizer, employees are exposed to fall hazards greater than 4 feet .    b) at the facility, platform around V-181, employees are exposed to fall hazards greater than 4 feet.
Recent events (2)
  • — I (S) $2675
  • — Z (S) $3750

1910.23 D01

Serious Gravity 1 1 instance 4 exposed
Issued
Jun 15, 2015
Abate by
Jul 18, 2015
Penalty
Initial $2,250 · Current $0 Reduced
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails:    a) at the facility, V-181 area, the stairs had the handrails removed and not replaced.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2250

1910.134 D01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 15, 2015
Abate by
Jul 18, 2015
Penalty
Initial $5,000 · Current $3,925 Reduced

Hazardous substances 1480

29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability:    (a) at ST-17, employees were required to use a full-face, air-purifying respirator for protection from hydrogen sulfide. A full-face air-purifying respirator is not approved for use with hydrogen sulfide, an asphyxiate.
Recent events (2)
  • — I (S) $3925
  • — Z (S) $5000

View Clean Harbors's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340498203.