OSHA Inspection: MARINE CORPS AIR GROUND COMBAT CENTER, MAGTFTC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARINE CORPS AIR GROUND COMBAT CENTER, MAGTFTC in PWD, ASSET MGT. - BLDG. 1130, TWENTYNINE PALMS MCB, CA 92278 (NAICS 928110). OSHA activity number 340504919.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Marine Corps AIR Ground Combat Center, Magtftc — free Get an email when a new federal OSHA severe-injury report for Marine Corps AIR Ground Combat Center, Magtftc is published. One employer, no account, unsubscribe in one click.
Site address
PWD, ASSET MGT. - BLDG. 1130
City
TWENTYNINE PALMS MCB
State
CA
ZIP
92278
Mailing
MAGTFTC, MCAGCC SAFETY BLDG. 1447, TWENTYNINE PALMS MCB, CA 92278
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
2200
Ownership type
D

6 citations on file for this inspection.

1910.36 G02

Serious Gravity 1 3 instances 3 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): An exit access was not at least 28 inches (71.1 cm) wide at all points and the width of the exit and exit discharge was not at least equal to the width of the exit access.  (a) At PWD Building 1130, Architect's office, exit access was 20 inches and obstructed by desk and file cabinets.  (b) At PWD Building 1130, Mechanical Engineer's office, exit access was 18 inches and obstructed by a desk.  (c) At PWD Building 1130, Resource Manager's office, exit access was 12 inches and obstructed by boxes.
Recent events (1)
  • — Z (S) $0

1910.37 B02

Serious Gravity 1 1 instance 28 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  (a) At PWD Building 1130, planning spaces exit door was not identified as an exit.
Recent events (1)
  • — Z (S) $0

1910.37 B04

Serious Gravity 1 1 instance 28 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent.  (a) At PWD Building 1130 planning area, the route to exit the building was not marked.
Recent events (1)
  • — Z (S) $0

1910.37 B05

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet).  (a) At PWD Building 1129, HVAC room door leading to the glass shop could be mistaken for an exit and was not marked.
Recent events (1)
  • — Z (S) $0

1910.101 B

Serious Gravity 5 2 instances 3 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): 29 CFR 1910.101(b):  Section 3.4.4, Compressed Gas Association Pamphlet P11965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinder(s) not in use were not properly supported to prevent them from being knocked over.  (a) At PWD Building 1129, behind HVAC Shop, stored compressed gas cylinders of nitrogen were not properly secured.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 4 instances 6 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  (a) At PWD Building 1130, Planners office, re-locatable power taps were daisy chained, one re-locatable power tap was connected to the other creating electrical hazards.  (b) At PWD Building 1130, Chief Engineers office, re-locatable power taps were daisy chained, one re-locatable power tap was connected to the other creating electrical hazards.  (c) At PWD Building 1130, Engineers office, a re-locatable power tap was connected from an extension cord to plug in electronics equipment.  (d) At PWD Building 1130, Resource Management office, a re-locatable power tap was used to plug in a refrigerator and a microwave oven.
Recent events (1)
  • — Z (S) $0

View Marine Corps AIR Ground Combat Center, Magtftc's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340504919.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.