CALHOUN, GA —
OSHA Inspection: APACHE MILLS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of APACHE MILLS, INC. in 197 ROYAL DRIVE, CALHOUN, GA 30701 (NAICS 326299). OSHA activity number 340505528.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- APACHE MILLS, INC.
- Site address
- 197 ROYAL DRIVE
- City
- CALHOUN
- State
- GA
- ZIP
- 30701
- Mailing
- 197 ROYAL DRIVE, CALHOUN, GA 30701
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326299
- Employees
- 468
- Ownership type
- A
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 29, 2015
- Abate by
- Oct 26, 2015
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by hazards: a. Press Room, Rubber Unload Hopper - The employer did not ensure that all below the hook lifting devices were constructed and load tested to prevent the below the hook lifting devices (i.e. shop made spreader bar used for lifting bags containing 2000 pounds of rubber) from failing which could strike and injure employees.
Recent events (2)
- — I (S) $4200
- — Z (S) $7000
1910.24 B
- Issued
- Sep 29, 2015
- Abate by
- Oct 26, 2015
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
29 CFR 1910.24(b): Fixed stairs were not provided for access from one structure level to another where operations necessitated regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations: a. Press lines 1 and 2 - The employer did not provide a safe means of access to the conveyors, which started and stopped without warning, thereby exposing employees to falls hazards. b. Rubber unload area - An employee accessed the rubber unloading deck twelve times per day. The unloading deck is 3 feet high. The employee is exposed to a fall hazard.
Recent events (2)
- — I (S) $4200
- — Z (S) $7000
1910.137 C02 VIII
- Issued
- Sep 29, 2015
- Abate by
- Oct 26, 2015
- Penalty
- Initial $5,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.137(c)(2)(viii): Electrical protective equipment shall be subjected to periodic electrical tests. Test voltages and the maximum intervals between tests shall be in accordance with Table I-4 and Table I-5. a. Maintenance area - The rubber insulative protective gloves had not been dielectrically tested on a periodic basis thereby exposing the employees to shock hazards.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
1910.212 A01
- Issued
- Sep 29, 2015
- Abate by
- Oct 26, 2015
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. Press room - The conveyors on Presses 1 and 2 were not guarded, thereby exposing employees to in running nip points located between the conveyor belt and end roller.
Recent events (2)
- — I (S) $4200
- — Z (S) $7000
1910.219 C04 I
- Issued
- Sep 29, 2015
- Abate by
- Oct 26, 2015
- Penalty
- Initial $6,000 · Current $3,600 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a. Press room - The (4) shaft ends on the feed conveyors for Presses 1 and 2 were not guarded, thereby exposing employees to caught by and crushing hazards.
Recent events (2)
- — I (S) $3600
- — Z (S) $6000
1910.332 B01
- Issued
- Sep 29, 2015
- Abate by
- Oct 26, 2015
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: a. Worksite - The employees who worked on or near live electrical parts were not trained in and familiar with safety related work practices, thereby exposing employees to shock and arc flash/blast hazards.
Recent events (2)
- — I (S) $4200
- — Z (S) $7000
1910.332 B02
- Issued
- Sep 29, 2015
- Abate by
- Oct 26, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.332(b)(2): Employees, who were not qualified persons, were not trained in and familiar with any electrically related safety practices not specifically addressed by 29 CFR 1910.331 through 29 CFR 1910.335, but which were necessary for their safety. a. Work-site - The unqualified maintenance workers who worked on and near potential live electrical equipment were not familiar with and trained in electrical safety related work practices, thereby exposing them to arc flash/blast and shock hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.333 A
- Issued
- Sep 29, 2015
- Abate by
- Oct 26, 2015
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized: a. Maintenance Department - Safety related work practices were not employed to prevent workers from receiving either shock or arc flash/blast injuries when working on or near and/or potentially energized circuits, conductors and equipment.
Recent events (2)
- — I (S) $4200
- — Z (S) $7000
1910.335 A01 I
- Issued
- Sep 29, 2015
- Abate by
- Oct 26, 2015
- Penalty
- Initial $5,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: a. Work-site - When unqualified employees worked on and near live electrical equipment, they were not provided with electrical protective equipment and specific personal protective equipment, thereby exposing them to shock and arc flash/blast hazards.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
More inspections at Apache Mills, INC.
View Apache Mills, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326299)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340505528.