Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BUREAU OF LAND MANAGEMENT - BAKERSFIELD FIELD OFFICE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BUREAU OF LAND MANAGEMENT - BAKERSFIELD FIELD OFFICE in SOUTH FORK FIRE STATION 30147 HWY 178, ONYX, CA 93255 (NAICS 922160). OSHA activity number 340512698.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bureau of Land Management - Bakersfield Field Office — free Get an email when a new federal OSHA severe-injury report for Bureau of Land Management - Bakersfield Field Office is published. One employer, no account, unsubscribe in one click.
Site address
SOUTH FORK FIRE STATION 30147 HWY 178
City
ONYX
State
CA
ZIP
93255
Mailing
3801 PEGASUS DR., BAKERSFIELD, CA 93308
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922160
Employees
5
Ownership type
D

11 citations on file for this inspection.

1910.134 C02 I

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 15, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  Engine bay: Employees voluntarily wearing N95 filtering face piece respirators not provided a copy of Appendix D of the respirator standard, and were unaware of the limitations and hazards of respirator use.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 15, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Engine shop: A drill press lacked a method of machine guarding to protect employees from flying chips and sparks.
Recent events (1)
  • — Z (S) $0

1910.213 B03

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 15, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure:  Engine Bay: A drill press lacked a method to prevent automatic restarting of the machine in the event of a power failure.
Recent events (1)
  • — Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 15, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  Engine Bay: Compressed air used by the employees for cleaning was not reduced to less than 30 p.s.i.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 2 instances 5 exposed
Issued
Apr 15, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) Engine bay: Employees exposed to electrical shock where a power strip was connected in series to another power strip to supply 120VAC service to shop equipment.  (b) Engine bay: Power strips were used in a shop environment.
Recent events (1)
  • — Z (S) $0

1910.303 B07 I

Serious Gravity 1 2 instances 5 exposed
Issued
Apr 15, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:  Office: Two receptacle boxes on the wall had conduit connection openings uncovered.
Recent events (1)
  • — Z (S) $0

1910.303 G01 II

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 15, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  Engine bay: A work bench and bench grinder stand were placed in front of an electrical shut off box controlling the service to the automotive lift equipment.
Recent events (1)
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 15, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:  Engine bay: The work bench power cord had a damaged sheath exposing the conductors.
Recent events (1)
  • — Z (S) $0

1904.32 A03

Other-than-serious 1 instance 1 exposed
Issued
Apr 15, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1904.32(a)(3): The employer did not certify an OSHA 300A Form or equivalent.  South Fork Fire Station: The employer did not create and certify an annual summary of injuries and illnesses for 2014.
Recent events (1)
  • — Z (O) $0

1904.32 A04

Other-than-serious 1 instance 1 exposed
Issued
Apr 15, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1904.32(a)(4): The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30.  South Fork Fire Station: The employer did not post an annual summary of injuries and illnesses for 2014.
Recent events (1)
  • — Z (O) $0

1904.40 A

Other-than-serious 1 instance 1 exposed
Issued
Apr 15, 2015
Abate by
May 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours.  South Fork Fire Station: The employer was unable to produce copies of the 2010, 2011, 2012, 2013 and 2014 log of injuries and illnesses for the field office.
Recent events (1)
  • — Z (O) $0

View Bureau of Land Management - Bakersfield Field Office's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340512698.