OSHA Inspection: U.S. MARINE CORPS AIR GROUND COMBAT CENTER, 29PALMS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. MARINE CORPS AIR GROUND COMBAT CENTER, 29PALMS in MCX ADMINISTRATION, BLDG. 1522, 29 PALMS, CA 92278 (NAICS 928110). OSHA activity number 340515592.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Marine Corps AIR Ground Combat Center, 29palms — free Get an email when a new federal OSHA severe-injury report for U.S. Marine Corps AIR Ground Combat Center, 29palms is published. One employer, no account, unsubscribe in one click.
Site address
MCX ADMINISTRATION, BLDG. 1522
City
29 PALMS
State
CA
ZIP
92278
Mailing
MCCS BLDG. 1533 MCAGCC - BOX 788150, 29 PALMS, CA 92278
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
120
Ownership type
D

7 citations on file for this inspection.

1910.36 G02

Serious Gravity 1 5 instances 4 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  (a)  At the MCCS Administration Bldg. 1522, admin officer's and general clerk's office, exit access were obstructed by book case, desk and furniture and were narrowed down to 14, 15, 23, and 26 inches wide.  (b) At the MCCS Human Resources Offices, recruiting lead, EEO counselor, training and director's room, exit access were obstructed by table, desk, round table, couch and furniture and were narrowed down to 22, 23 and 26 inches.
Recent events (1)
  • — Z (S) $0

1910.37 B02

Serious Gravity 1 5 instances 4 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit".  (a) At the MCCS Human Resources Benefits room, exit door was not marked "EXIT.
Recent events (1)
  • — Z (S) $0

1910.37 B05

Serious Gravity 1 2 instances 4 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet).  (a) At the MCCS Human Resources Benefits room, door leading to the storage room was not marked "NOT AN EXIT.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  (a) At the Management Information System, a re-locatable power tap was used to plug in the gold star microwave oven and a black and decker coffee maker.
Recent events (1)
  • — Z (S) $0

1910.304 F01 IV

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel.  (a) At the Management Information System UPS room, the safety switch for E circuit 2.4.6 was obstructed by computer work bench.
Recent events (1)
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Covers of outlet boxes having holes through which flexible cord pendants passed were not provided with bushings designed for the purpose nor did the holes have smooth, well-rounded surfaces on which the cords could bear.  (a) At the MCCS HR ADR Office, the energized electrical wall outlet receptacle had a broken cover.
Recent events (1)
  • — Z (S) $0

1910.157 E02

Other-than-serious 2 instances 8 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly.  (a)  At the MCCS - Main Exchange Warehouse Bldg. 1533 employee break room, the portable fire extinguisher was not inspected monthly, the last inspection date was September 2014.  (b) At the MCCS - Management Information System, the portable fire extinguisher was not inspected monthly, the last inspection date was April 2014.
Recent events (1)
  • — Z (O) $0

View U.S. Marine Corps AIR Ground Combat Center, 29palms's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340515592.