Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. MARINE CORPS AIR GROUND COMBAT CENTER, 29PALMS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. MARINE CORPS AIR GROUND COMBAT CENTER, 29PALMS in MAINTENANCE OFFICE MCCS BLDG 2316 T2, 29 PALMS, CA 92278 (NAICS 928110). OSHA activity number 340521558.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Marine Corps AIR Ground Combat Center, 29palms — free Get an email when a new federal OSHA severe-injury report for U.S. Marine Corps AIR Ground Combat Center, 29palms is published. One employer, no account, unsubscribe in one click.
Site address
MAINTENANCE OFFICE MCCS BLDG 2316 T2
City
29 PALMS
State
CA
ZIP
92278
Mailing
MCCS DIRECTORATE BLDG 1522 MCAGCC BOX 788150, 29 PALMS, CA 92278
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
120
Ownership type
D

3 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.  (a)  At the MCCS Maintenance Office Bldg. 2316T2, the hot water heater area room was cluttered with PVC pipes, water cooler,  coffee pot, boxes and other materials.
Recent events (1)
  • — Z (S) $0

1910.36 G02

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  (a)  At the MCCS Maintenance Office Bldg. 2316T2, exit access was 21 inches and obstructed by a desk and file cabinet.
Recent events (1)
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  (a)  At the MCCS Maintenance Office Bldg. 2316T2, oxygen and acetylene gas cylinders were in storage together for more than 30 days.
Recent events (1)
  • — Z (S) $0

View U.S. Marine Corps AIR Ground Combat Center, 29palms's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340521558.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.