LITTLE NECK, NY —
OSHA Inspection: WING JAY CONSTRUCTION INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WING JAY CONSTRUCTION INC in 41-24 LITTLE NECK PARKWAY, LITTLE NECK, NY 11363 (NAICS 236115). OSHA activity number 340520873.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WING JAY CONSTRUCTION INC
- Site address
- 41-24 LITTLE NECK PARKWAY
- City
- LITTLE NECK
- State
- NY
- ZIP
- 11363
- Mailing
- 50-18 203RD STREET, FLUSHING, NY 11364
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.100 A
- Issued
- Apr 10, 2015
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about April 7, 2015- job site at 41-24 Little Neck Parkway, Little Neck, NY 11363 the employer permitted employees to work at a residential construction site, where overhead brick work was being performed, without wearing protective helmets. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.403 B02
- Issued
- Apr 10, 2015
- Abate by
- Apr 29, 2015
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On or about April 7, 2015- job site at 41-24 Little Neck Parkway, Little Neck, NY 11363 The employer permitted their employees to use a wall outlet, that was not properly installed, to power a portable cement mixer. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.404 B01 I
- Issued
- Apr 10, 2015
- Abate by
- Apr 29, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) On or about April 7, 2015- job site at 41-24 Little Neck Parkway, Little Neck, NY 11363 Employer permitted their employees to use a electrically powered cement mixer, out doors, that was not protected by a GFCI. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B01 II
- Issued
- Apr 10, 2015
- Abate by
- Apr 29, 2015
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm): a) On or about April 7, 2015- jobsite at 41-24 Little Neck Parkway, Little Neck, NY 11363 The employer permitted their employees to work on a tubular welded frame scaffold, approximately 13 feet above the next lower level, that was not fully planked WRITEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.451 C01 I
- Issued
- Apr 10, 2015
- Abate by
- Apr 29, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(1)(i): Guys, ties, and braces were not installed at locations where horizontal members support both inner and outer legs: a) On or about April 7, 2015- job site at 41-24 Little Neck Parkway, Little Neck, NY 11363 The employer permitted their employees to work on a tubular welded framed scaffold, approximately 13 feet above the next lower level, that was missing cross braces. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02 I
- Issued
- Apr 10, 2015
- Abate by
- Apr 29, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: a) On or about April 7, 2015- job site at 41-24 Little Neck Parkway, Little Neck, NY 11363 The employer permitted their employees to work on a tubular welded framed scaffold, approximately 13 feet above the next lower level, that had its footing on loose and broken bricks. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Apr 10, 2015
- Abate by
- Apr 29, 2015
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) On or about April 7, 2015- job site at 41-24 Little Neck Parkway, Little Neck, NY 11363 The employer permitted their employees to work on a tubular welded frame scaffold, approximately 13 feet above the next lower level, without fall protection. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.451 F06
- Issued
- Apr 10, 2015
- Abate by
- Apr 29, 2015
- Penalty
- Initial $2,800 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section: a) On or about April 7, 2015- job site at 41-24 Little Neck Parkway, Little Neck, NY 11363 The employer permitted their employees to work on and near a tubular welded frame scaffold, that was in contact with an insulated power drop, supplying power to the home. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $1200
- — Z (S) $2800
More inspections at Wing JAY Construction INC
View Wing JAY Construction INC's full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340520873.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.