BROOKLYN, NY —
OSHA Inspection: SNACK INNOVATIONS INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SNACK INNOVATIONS INC. in 67 35TH STREET 3RD FLOOR, BROOKLYN, NY 11232 (NAICS 311919). OSHA activity number 340553874.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SNACK INNOVATIONS INC.
- Site address
- 67 35TH STREET 3RD FLOOR
- City
- BROOKLYN
- State
- NY
- ZIP
- 11232
- Mailing
- 67 35TH STREET 3RD FLOOR, BROOKLYN, NY 11232
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311919
- Employees
- 25
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.37 A03
- Issued
- Oct 7, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $2,800 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not free and/or unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp were not provided where the exit route was not substantially level. Site: 67 35th Street Brooklyn, NY On or about 4/14/15 a) The pathway leading to the emergency exit door in the warehouse area was blocked. the emergency exit door leading to the Fire Escape was blocked by boxes and other stored materials.
Recent events (2)
- — I (S) $1800
- — Z (S) $2800
1910.147 C01
- Issued
- Oct 7, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $2,800 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure and employee training to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury. Site: 67 35th Street Brooklyn, NY On or about 4/14/15 a) The employer did not have a Lock Out/Tag Out written program consisting of energy control to protect the employees fro accidental start up of the equipment.
Recent events (2)
- — I (S) $1800
- — Z (S) $2800
1910.147 C04 I
- Issued
- Oct 7, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. Site: 67 35th Street Brooklyn, NY On or about 4/14/15 a) The employer did not implement Lock Out/Tag Out procedures to isolate the popcorn and chips machinery equioment from its power source.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C05 I
- Issued
- Oct 7, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources such as (pneumatic, hydraulic, electric, gravity, etc.). Site: 67 35th Street Brooklyn, NY On or about 4/14/15 a) The employer did not provide hardware such as but not limited to; locks, tags, blocks, wedges and pins for isolating, securing the equipment from start up.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Oct 7, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program were understood by authorized, affected, and other employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by authorized employees. Site: 67 35th Street Brooklyn, NY On or about 4/14/15 a) No adequate training was provided by the employer to ensure that the purpose and function of the energy control program was understood by employees.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- Oct 7, 2015
- Abate by
- Oct 20, 2015
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries. Site: 67 35th Street Brooklyn, NY On or about 4/14/15 a) A fire extinguisher located in the rear of the warehouse was blocked by boxes and other stored merchandise. It was not immediately accessible for use.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
More inspections at Snack Innovations INC.
View Snack Innovations INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311919)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340553874.