Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FORWARD AIR, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FORWARD AIR, INC. in 480 MCCLELLAN HIGHWAY, EAST BOSTON, MA 02228 (NAICS 484122). OSHA activity number 340559368.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Forward AIR, INC. — free Get an email when a new federal OSHA severe-injury report for Forward AIR, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FORWARD AIR, INC.
Site address
480 MCCLELLAN HIGHWAY
City
EAST BOSTON
State
MA
ZIP
02228
Mailing
480 MCCLELLAN HIGHWAY, EAST BOSTON, MA 02228
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484122
Employees
33
Ownership type
A

7 citations on file for this inspection.

1910.132 A

Serious Gravity 1 1 instance 8 exposed
Issued
Aug 14, 2015
Abate by
Nov 18, 2015
Penalty
Initial $3,000 · Current $2,100 Reduced
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and maintained in a sanitary and reliable condition:    Establishment:    For employees who change out propane tanks on the forklift trucks, adequate personal protective equipment was not provided and maintained in a sanitary condition:  a) The gloves available on site did not provide adequate protection against physical and chemical injury.  b) Employer did not ensure that the face shield provided was used and maintained in a sanitary condition.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3000

1910.151 C

Deleted Serious Gravity 5 1 instance 8 exposed
Issued
Aug 14, 2015
Abate by
Nov 18, 2015
Penalty
Initial $4,000 · Current $0 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  Rear Right Corner of Warehouse:  Where hazardous materials were stored, suitable flushing facilities for eyes and face were not provided for employees who transport and store hazardous materials and were exposed to corrosive liquids such as phosphoric acid.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4000

1910.176 A

Serious Gravity 5 1 instance 8 exposed
Issued
Aug 14, 2015
Abate by
Nov 18, 2015
Penalty
Initial $4,000 · Current $2,800 Reduced
29 CFR 1910.176(a): Aisle(s) and passageway(s) were not kept clear and in good repair with no obstruction across or in aisles that could create a hazard:    Rear Left Corner of Warehouse:    There was an unsecure stack of wooden pallets and crates that restricted the access in a passageway for the forklift trucks to traverse to the rear left corner of the warehouse.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4000

1910.176 B

Serious Gravity 5 1 instance 8 exposed
Issued
Aug 14, 2015
Abate by
Nov 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:  Rear Left Corner of Warehouse:  Where forklift trucks were used and pedestrians traverse, wooden pallets and crates that were stacked in a pile greater than five (5) feet in height, were not adequately stacked, tiered and/or limited in height to prevent sliding and collapsing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 F01 IV

Serious Gravity 5 1 instance 8 exposed
Issued
Aug 14, 2015
Abate by
Nov 18, 2015
Penalty
Initial $4,000 · Current $2,800 Reduced
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were located in the vicinity of easily ignitable material and/or were not readily accessible to each employee or authorized building management personnel:    Warehouse:    The following overcurrent devices and disconnects for circuits rated for 600 volts or less that energized equipment such as lighting were blocked by items (some easily ignitable materials) in storage:  a) Left rear corner - 2 circuit panels and a transformer were blocked items such as cardboard boxes, a large wooden crate, 2 plastic 5-gallon buckets and metal bars.  b) Right rear corner -  4 disconnects were blocked by hazardous materials in storage such as a 55-gallon drum of motor oil, a 55+ gallon container of hazardous material waste, large cardboard box filled with items in storage and a cage that held 12 propane tanks and at least 2 free standing propane tanks.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4000

1910.157 C01

Other-than-serious 1 instance 8 exposed
Issued
Aug 14, 2015
Abate by
Nov 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  Rear Left Corner of Warehouse:   The portable fire extinguisher located adjacent to the exit door was not mounted or secured.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 8 exposed
Issued
Aug 14, 2015
Abate by
Nov 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  Establishment:  Employer did not develop and implement a written Hazard Communication Program as required by this section for employees who transport hazardous materials and were exposed to various hazardous materials (some corrosive) such as phosphoric acid.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Forward AIR, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340559368.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.