OSHA Inspection: LAPP ELECTRICAL SERVICES INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of LAPP ELECTRICAL SERVICES INC. in 2913 SPOOKY NOOK RD., MANHEIM, PA 17545 (NAICS 238210). OSHA activity number 340559822.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lapp Electrical Services INC. — free Get an email when a new federal OSHA severe-injury report for Lapp Electrical Services INC. is published. One employer, no account, unsubscribe in one click.
Site address
2913 SPOOKY NOOK RD.
City
MANHEIM
State
PA
ZIP
17545
Mailing
2420 GEHMAN LANE, LANCASTER, PA 17602
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
30
Ownership type
A

2 citations on file for this inspection.

1926.403 B02

Other-than-serious 1 instance 4 exposed
Issued
Jun 10, 2015
Abate by
Jul 7, 2015
Penalty
Initial $3,500 · Current $2,500 Reduced
instance b replaced as follows per ISA dated July 2, 2015      b)  Northeast Hotel Wing, 3rd Floor Stairwell Landing: On or about April 16, 2015 a 12/2 NM (non-metallic) cable was spliced to cable for a temporary lighting string, where the area of the cable splice was not protected from damage or contact.  The cable splice was located 48 above the work surface, and not otherwise protected from damage.    -------------------------------------------------------------------------------------------------------------------------------------------            29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    a) Northeast 2nd Floor Hotel Wing: A 12/2 NM (non-metallic) cable was wired directly into a cord cap (male plug end) which was drawing power from a duplex electrical outlet.  NM cable is listed and labeled to be used for branch circuits into electrical boxes not into reloadable service plugs, thereby exposing employees to an electrical hazard on or about April 16, 2015.    b) Southeast 2nd Floor Hotel Wing: A 12/2 NM (non-metallic) cable was wired directly into a cord cap (male plug end) which was drawing power from a duplex electrical outlet.  NM cable is listed and labeled to be used for branch circuits into electrical boxes not into reloadable service plugs, thereby exposing employees to an electrical hazard on or about April 16, 2015.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $2500
  • — Z (S) $3500

1926.405 G02 III

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jun 10, 2015
Abate by
Jul 7, 2015
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap:  a)  NORTHEAST HOTEL WING, 3RD FLOOR STAIRWELL LANDING:  On or about April 16, 2015 a 12/2 NM (non-metallic) cable was spliced with a 14/2 minimum duty flat (flexible) cord exposing employees to shock hazards. The 14/2 flat cord splice located 48" above the working surface is not used in a continuous length, does not retain the insulation, outer sheath properties and usage characteristics to be used in this manner.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.