Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MARIANAS PROPERTY LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARIANAS PROPERTY LLC in 627 SAN VITORES ROAD, TAMUNING, GU 96913 (NAICS 721110). OSHA activity number 340578038.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Marianas Property LLC — free Get an email when a new federal OSHA severe-injury report for Marianas Property LLC is published. One employer, no account, unsubscribe in one click.
Site address
627 SAN VITORES ROAD
City
TAMUNING
State
GU
ZIP
96913
Mailing
627 PALE SAN VITORES ROAD, TAMUNING, GU 96913
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
240
Ownership type
A

6 citations on file for this inspection.

1910.36 D01

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 11, 2015
Penalty
Initial $2,168 · Current $1,518 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:   Supply Storage - An exit door was bolted shut at the top of the door, preventing safe and immediate egress in the event of a fire or other emergency.
Recent events (2)
  • — I (S) $1517.6
  • — Z (S) $2168

1910.134 F02

Serious Gravity 5 3 instances 3 exposed
Issued
Jun 11, 2015
Abate by
Jun 25, 2015
Penalty
Initial $3,400 · Current $2,380 Reduced
29 CFR 1910.134(f)(2): The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter.     Maintenance - The employer did not ensure that employees donning 3M tight-fitting negative pressure respirators, 3M N-95 respirators, and SCBAs for emergency use received annual fit testing as required.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $3400

1910.134 H03 III

Serious Gravity 1 2 instances 2 exposed
Issued
Jun 11, 2015
Abate by
Jun 17, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(3)(iii): Self-contained breathing apparatus was not inspected monthly:   Safety and Security Department - Two Survivair SCBAs intended for emergency use were not inspected monthly.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K05

Serious Gravity 1 4 instances 4 exposed
Issued
Jun 11, 2015
Abate by
Jul 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(5): Respiratory protection retraining was not conducted annually:  Maintenance/Engineering and the Safety/Security Departments - The employer did not provide annual training to employees wearing respirators.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 L01

Serious Gravity 1 1 instance 4 exposed
Issued
Jun 11, 2015
Abate by
Jul 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(l)(1): Evaluations of the workplace were not conducted to ensure the written respiratory protection program was being effectively implemented:  Maintenance/Engineering and the Safety/Security Departments - An evaluation of the workplace was not conducted once hotel ownership changed to ensure that the respiratory protection program was effectively implemented.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 11, 2015
Penalty
Initial $2,168 · Current $1,518 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.   Control Plant - Oxygen and acetylene cylinders not in use were stored together.
Recent events (2)
  • — I (S) $1517.6
  • — Z (S) $2168

View Marianas Property LLC's full OSHA safety record →