Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALUMINUM SHAPES, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ALUMINUM SHAPES, LLC. in 9000 RIVER ROAD, DELAIR, NJ 08110 (NAICS 331316). OSHA activity number 340593680.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aluminum Shapes, LLC. — free Get an email when a new federal OSHA severe-injury report for Aluminum Shapes, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
9000 RIVER ROAD
City
DELAIR
State
NJ
ZIP
08110
Mailing
9000 RIVER ROAD, DELAIR, NJ 08110
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331316
Employees
398
Ownership type
A

63 citations on file for this inspection.

1910.23 A05

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $6,000 · Current $3,500 Reduced
29 CFR 1910.23(a)(5): For every pit and/or trap door floor opening, while the cover was not in place, was not constantly attended by someone or was not protected on all exposing sides by removable standard railings:      a)  Building 10, Danieli Press Area: An attendant was not present and guardrails were not in use while the door to the Danieli butt chute pit was open, on or about 5/13/2015.
Recent events (3)
  • — J (S) $3500
  • — C (S) $6000
  • — Z (S) $6000

1910.23 A08

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $4,000 · Current $1,500 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded:    a)9000 River Rd, Delair, NJ- Building 10, Danieli Rack Lift Area: Employees worked in the vicinity of the rack lift location where there were unguarded floor holes while working with small racks which was observed on or about 6/22/15.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $1500
  • — C (S) $4000
  • — Z (S) $4000

1910.23 C01

Serious Gravity 10 2 instances 2 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $7,000 · Current $4,500 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    a)9000 River Rd, Delair, NJ- Building 3 Back Bay/ Loading Dock:  Employees worked on open sided floors or platforms between 52 and 60 inches in height which were not guarded by standard rail (or equivalent- chains), observed on or about 6/22/15.    b)9000 River Rd, Delair, NJ- Foundry:  Employees worked on open sided floors eight to ten feet around the furnace which were not guarded by standard rail (or equivalent- chains), observed on or about 5/13/15.    NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (S) $4500
  • — C (S) $7000
  • — Z (S) $7000

1910.23 E03 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $6,000 · Current $3,500 Reduced
29 CFR 1910.23(e)(3)(iv): The anchoring of posts and framing of members for railings of all types were not of such construction that the completed structure was not capable of withstanding a load of at least 200 pounds applied in any direction at any point on the top rail:    a)9000 River Rd, Delair, NJ- Building 3, Back Bay/Shipping Area: Employees loaded trailers or placed orders to be loaded on loading docks at a height of approximately 52 up to 60 inches where vertical posts were not attached or anchored to the loading dock and capable of withstanding 200 pounds of force which was observed on or about 4/16/15.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $3500
  • — C (S) $6000
  • — Z (S) $6000

1910.24 H

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $4,000 · Current $1,500 Reduced
29 CFR 1910.24(h): "Railings and handrails." Standard railings were not provided on the open sides of all exposed stairways and stair platforms. Stair railings and handrails were not installed in accordance with the provisions of 1910.23.    a)9000 River Rd, Delair, NJ, Building 10 Shipping Area: Employees used a stairway for access and egress to and from building 10 which was not provided with railings on it's open side and was observed on 5/13/15.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $1500
  • — C (S) $4000
  • — Z (S) $4000

1910.36 G02

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 22, 2015
Abate by
Jan 31, 2016
Penalty
Initial $3,000 · Current $500 Reduced
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.    a)9000 River Rd, Delair, NJ Saw House (number 2 billet saw): Exit access along the table was 11 inches wide, observed on or about 4/16/15.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $500
  • — C (S) $3000
  • — Z (S) $3000

1910.37 A03

Serious Gravity 1 3 instances 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    a)9000 River Rd, Delair, NJ- Building 11 Shipping Area: The exit door was blocked by a motor, observed on or about 5/13/15.    b)9000 River Rd, Delair, NJ Saw House (number 2 billet saw): A reel of steel taping was placed in front of the door, which would not allow the door to open in the event of an emergency, observed on or about  4/16/15.    c)9000 River Rd, Delair, NJ- Die Correction: The exit door was blocked by stored dies, observed on or about 8/6/15.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.146 E01

Serious Gravity 5 2 instances 7 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.146(e)(1): Before entry was authorized, the employer did not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit:    a) 9000 River Rd, Delair, NJ, Foundry: Entry permits were not filled out prior to foundry employees entering the areas under the furnaces, occurred on or about 5/13/2015.    b) 9000 River Rd, Delair, NJ, Foundry: Entry permits were not filled out prior to foundry employees entering the casting pit, occurred on or about 5/13/2015.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.146 G01

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146:    (a) 9000 River Rd, Delair, NJ- Foundry: Permit required confined space training had not been provided to employees who enter permit required confined spaces which include but are not limited to areas beneath the furnaces and the casting pit, occurred on or about 5/13/2015.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.146 K01 IV

Serious Gravity 5 3 instances 6 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.146(k)(1)(iv): The employer who had designated rescue and emergency services did not inform each rescue team or service of the hazards they may confront when called to perform rescue at the site:    a)9000 River Rd, Delair, NJ- Foundry: The Pennsauken Fire Department, who the employer designated to perform permit required confined space rescue, was not informed of the hazards they may confront when called to perform rescue at the facility where employees performed cleaning and maintenance of the areas beneath the casting pit which occurred on or about 5/13/15.    b)9000 River Rd, Delair, NJ- Foundry: The Pennsauken Fire Department, who the employer designated to perform permit required confined space rescue, was not informed of the hazards they may confront when called to perform rescue at the facility where employees performed cleaning and maintenance of the areas beneath the holding furnace which occurred on or about 5/13/15.    c)b)9000 River Rd, Delair, NJ- Anodizing: The Pennsauken Fire Department, who the employer designated to perform permit required confined space rescue, was not informed of the hazards they may confront when called to perform rescue at the facility where employees performed cleaning and maintenance of the anodizing tanks which occurred on or about 5/13/15.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.147 C04 II

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):    a)9000 River Rd, Delair, NJ- Building 6 Sutton 3 Press: A specific energy control procedure was not documented to be utilized for maintenance to shut down the Sutton 3 press, occurred on or about 6/10/15.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.147 C04 II B

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $7,000 · Current $4,500 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.    a) 9000 River Road, Delair, NJ, Foundry: Energy control procedure for the furnace did not include procedures on the placement of blocking devices to prevent the furnace from drifting down while employees entered the pit to clean, observed on or about 8/6/2015.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (S) $4500
  • — C (S) $7000
  • — Z (S) $7000

1910.147 D03

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:    (a) 9000 River Road, Delair, NJ, Foundry: Blocking devices were not installed to prevent the furnace from drifting down while employees entered the pit to clean, occurred on or about 5/13/2015.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 F03 II D

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment:    a)9000 River Rd, Delair, NJ- Foundry (Holding Furnace): Each employee working in a crew under the melting/holding furnace did not apply a personal lock, occurred on or about 5/13/15.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.157 C04

Serious Gravity 1 2 instances 25 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $3,000 · Current $500 Reduced
29 CFR 1910.157(c)(4): Portable fire extinguishers were not kept in their designated places at all times except during use:    (a) Facility located at 9000 River Road, Delair, NJ, Building 1 Near Extrusion Fabricating Cutting Machine: A portable fire extinguisher was missing from its designated area, observed on or about 6/22/15.     (b) Facility located at 9000 River Road, Delair, NJ, Anodizing: A portable fire extinguisher was missing from its designated area, observed on or about 8/6/15.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $500
  • — C (S) $3000
  • — Z (S) $3000

1910.157 E02

Serious Gravity 1 5 instances 25 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:    a) Facility located at 9000 River Road, Delair, NJ, Oil Water Separator Area: Two Amerex portable fire extinguishers were not subject to a monthly inspection, observed on or about 5/13/15.     b) Facility located at 9000 River Road, Delair, NJ, Billet #2: Two portable fire extinguishers were not provided with a monthly inspection, observed on or about 4/16/2015.    c) Facility located at 9000 River Road, Delair, NJ, Daneili Press: A portable fire extinguishers was not provided with a monthly inspection, observed on or about 4/16/2015.    c) Facility located at 9000 River Road, Delair, NJ, Anodizing: A portable fire extinguishers was not provided with a monthly inspection, observed on or about 4/16/2015.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.157 E03

Serious Gravity 1 5 instances 25 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:    a) Facility located at 9000 River Road, Delair, NJ, Oil Water Separator Area: Two Amerex portable fire extinguishers were not subject to an annual inspection, observed on or about 5/13/15.     b) Facility located at 9000 River Road, Delair, NJ, Billet #2: Two portable fire extinguishers were not provided with an annual inspection, observed on or about 4/16/2015.    c) Facility located at 9000 River Road, Delair, NJ, Daneili Press: A portable fire extinguishers was not provided with an annual inspection, observed on or about 4/16/2015.    d)Facility located at 9000 River Road, Delair, NJ, Anodizing: A portable fire extinguishers was not provided with an annual inspection, observed on or about 4/16/2015.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.157 G02

Serious Gravity 1 1 instance 25 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:    (a) Facility located at 9000 River Road, Delair, NJ: Employees who were expected to use a portable fire extinguisher in the event of an incipient stage fire were not provided with training upon initial hiring and at least annually thereafter, occurred on or about 5/13/15.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.178 A06

Serious Gravity 5 2 instances 1 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $4,000 · Current $1,500 Reduced
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates and markings were in place:    a) 9000 River Rd, Delair, NJ- Foundry:  Employees were operating a forklift with an attachment which did not have all nameplates and markings in place for purposes including but not limited hoisting aluminum furnace doors  observed 5/13/15.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $1500
  • — C (S) $4000
  • — Z (S) $4000

1910.179 G01 IV

Serious Gravity 5 6 instances 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.179(g)(1)(iv): Multiple conductor cable was used with a suspended pushbutton station, but the station was not supported in some satisfactory manner that protected the electrical conductors against strain:    a)9000 River Rd, Delair, NJ- Building 4, P&H 10 ton crane, number 2011: The pendant control box was lacking strain relief where the drop cord met the box, observed on or about 6/23/2015.      NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.179 J01 II B

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.179(j)(1)(ii)(b): 29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months:      (a) 9000 River Rd, Delair, NJ- Building 2, crane number 218: A complete inspection of the crane had not been completed since 2013, observed on or about 5/13/2015.       (b) 9000 River Rd, Delair, NJ- Building 4, P&H 10 ton crane, number 2011: A complete inspection of the crane had not been completed since 2013, observed on or about 5/13/2015.      NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.179 J02 III

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, were not performed:     a)9000 River Road, Delair, NJ Facility wide: Monthly inspections with written certifications were not performed on the hook used to rig loads throughout the facility, occurred on or about 5/13/15.       NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.179 J02 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed:    a)9000 River Road, Delair, NJ Facility wide: Monthly inspections with written certifications were not performed on the chains used to rig loads throughout the facility, occurred on or about 5/13/15.       NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.179 M01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.179(m)(1): Thorough monthly inspections of rope conditions, with written, dated and signed reports, were not performed on the running ropes:    a)9000 River Road, Delair, NJ Facility wide: Monthly inspections with written certifications were not performed on the running ropes used throughout the facility, occurred on or about 5/13/15.       NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 8 instances 10 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)9000 River Rd, Delair, NJ- Building 11, Fabrication Shop: Employees operated a Wilton Horizontal band saw to cut materials such as but not limited to metal and plastic with approximately five inches of the unused portion of the blade exposed, which occurred on or about and at times prior thereto 5/13/15.    b)9000 River Rd, Delair, NJ- Building 1, Fabrication Machine Shop: Employees operated a 1" belt sander to fabricate parts without a guard to protect employees from flying chips or particles, observed on or about 4/16/15.    c)9000 River Rd, Delair, NJ- Building 11, Fabrication Machine Shop: Employees operated a Birmingham Lathe (machine 2124) without a guard to protect from the rotating action of the chuck and part,  on or about 4/16/15.    d)9000 River Rd, Delair, NJ- Building 1, Fabrication Machine Shop: Employees operated a South Bend Precision Lathe without a guard to protect from the rotating action of the chuck and part, on or about 4/16/15.    e)9000 River Rd, Delair, NJ- Building 1, Fabrication Machine Shop: Employees used a Bridgeport milling machine and a Victor milling machine without a guard to protect from the rotating action of the chuck to fabricate parts,  on or about 4/16/15.    f)9000 River Rd, Delair, NJ- Building 1, Fabrication Shop; Employees used a Oliver metal cutting saw (internal machine 117) with insufficient chip guarding, on or about 6/22/15.    g)9000 River Rd, Delair, NJ- Building 1, Fabrication Shop: Employees operated a Drill Press (6020-4) without a guard to protect from the rotating action of the chuck to fabricate aluminum products, on or about 5/13/15.    h)9000 River Rd, Delair, NJ- Building 10, Danieli Press: Employees took measurements of aluminum extruded products at the Danieli press which was not guarded to prevent employees from having any part of their body in the danger zone during the operating cycle, occurred on or about 7/19/15    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.212 B

Serious Gravity 5 4 instances 2 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    a)9000 River Rd, Delair, NJ- Mold Maintenance: Employees were exposed to an eight inch Dayton pedestal grinder which was not securely anchored to prevent moving occurred on or about and at times prior thereto 4/16/15.     b)9000 River Rd, Delair, NJ- Fabrication Machine Shop: Employees were exposed to a Baldor pedestal grinder-buffer which was not securely anchored to prevent moving occurred on or about and at times prior thereto 4/16/15.    c)9000 River Rd, Delair, NJ- Fabrication Machine Shop: Employees were exposed to a Baldor pedestal grinder which was not securely anchored to prevent moving occurred on or about and at times prior thereto 4/16/15.    d)9000 River Rd, Delair, NJ- Fabrication Machine Shop: Employees were exposed to a Baldor pedestal grinder which was not securely anchored to prevent moving occurred on or about and at times prior thereto 4/16/15.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.213 H03

Serious Gravity 5 3 instances 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.213(h)(3): Radial saw(s) were not provided with an adjustable stop to prevent the forward travel of the blade beyond the position necessary to complete the cut in repetitive operations:    a)9000 River Rd, Pennsauken, NJ- Building 11, Shipping Department: Employees were operating radial arm saws which did not properly stop the forward travel of the blade used to cut wood for palletization of aluminum products to be shipped, which was observed on or about 4/16/15.    b)9000 River Rd, Pennsauken, NJ- Building 3, Shipping Department: Employees were operating radial arm saws which did not properly stop the forward travel of the blade used to cut wood for palletization of aluminum products to be shipped, which was observed on or about 5/13/15.    c)9000 River Rd, Pennsauken, NJ- Building 6, Shipping Department: Employees were operating radial arm saws which did not properly stop the forward travel of the blade used to cut wood for palletization of aluminum products to be shipped, which was observed on or about 6/22/15.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.213 H04

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator:    a)9000 River Rd, Pennsauken, NJ- Building 10, Shipping Department: Employees were operating radial saws that were not installed so as to cause the cutting head to return to the starting position when released, observed on or about 4/16/15.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.215 A04

Serious Gravity 5 2 instances 4 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    a) Facility, Building 1, Machine Shop: The work rests were not properly adjusted on the Baldor pedestal grinder, W10-91. The left opening measured 1/4 of an inch away from the abrasive wheel and the opening on the right measured 1/2 of an inch away from the abrasive wheel, on or about 5/13/2015.    b)a)9000 River Rd, Delair, NJ- Mold Maintenance: The work rests were not properly adjusted on the eight inch Dayton pedestal grinder, on or about 4/16/15.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.215 B09

Serious Gravity 5 2 instances 4 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    (a)  Facility, Building 1, Machine Shop: The tongue guards were not properly adjusted on the Baldor pedestal grinder, W10-91. The left opening measured 1/2 of an inch away from the abrasive wheel and the opening on the right also measured 1/2 of an inch away from the abrasive wheel, on or about 5/13/2015.    (b) 9000 River Rd, Delair, NJ- Mold Maintenance: The tongue guards were not properly adjusted on the eight inch Dayton pedestal grinder,  on or about 4/16/15    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a)9000 River Rd, Delair, NJ, Building 1, Fabrication shop: Employees operated a Wales drilling machine (internal machine number 1864) with the pulleys unguarded at approximately 65 inches observed on or about 5/13/15.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.219 E01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:    a)9000 River Rd, Delair, NJ, Building 1, Fabrication shop: Employees operated a Wales Drilling Machine (internal machine number 1864) with the belts unguarded at approximately 65 inches observed on or about 5/13/15.      NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.219 F03

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven 7 feet or less above floors or platforms were not enclosed:    a)9000 River Rd, Pennsauken, NJ- Stretcher Area: Employees worked near unguarded sprocket and chain wheels, below waist level less than seven feet above the floor on the Danieli press, which were not enclosed in the stretcher area on or about 4/16/15.      NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.242 B

Serious Gravity 5 2 instances 4 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a)9000 River Rd, Delair, NJ- Machine Shop: Employees worked with compressed air for cleaning parts and equipment which was not reduced to less than 30 PSI, occurred on or about 5/13/15.    b)9000 River Rd, Delair, NJ- Building 10 Shipping Area: Employees worked with compressed air for cleaning parts and equipment which was not reduced to less than 30 PSI, observed on or about 6/22/15.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.252 B02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:    a)9000 River Rd, Delair, NJ- Building 1 Rack Maintenance Area: Employees welding in the rack maintenance area were not using screens to protect employees in the areas adjacent to main roll-up door to the exterior, occurred on or about and at times prior thereto 4/16/15.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.253 B02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $4,000 · Current $1,500 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders were not stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces were not located where cylinders would not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:    a)9000 River Rd, Delair, NJ- Mold Maintenance: an oxygen cylinder was not stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. the same cylinder was not stored in a definitely assigned place where cylinders would not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Observed on or about 4/16/15.     NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (3)
  • — J (S) $1500
  • — C (S) $4000
  • — Z (S) $4000

1910.253 B04 I

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near another substance likely to cause or accelerate fire; or in an acetylene generator compartment:      a)9000 River Rd, Delair, NJ, behind building 4, gas storage area: Oxygen and Fuel gases were stored together in the same location, occurred on or about 4/16/15    b)9000 River Rd, Delair, NJ, behind building 10, gas storage area: Oxygen and Fuel gases were stored together in the same location, occurred on or about 4/16/15    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.303 B08 I

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.303(b)(8)(i): Electric equipment shall be firmly secured to the surface on which it is mounted.    a)9000 River Rd, Delair, NJ- Foundry: A 120V/25A four outlet junction box was not secured to the structural member it hung from, observed on or about 4/16/15.     NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a)9000 River Rd, Delair, NJ- Foundry Electrical Room- A 120V 2 outlet GFCI receptacle in a 4 gang metallic knockout box was not used as listed or labeled, observed on or about 4/16/15.     NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 3 instances 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    a)9000 River Rd, Delair, NJ- Fabrication Machine Shop, DS Row Section: Electrical panel boxes including but not limited to panels rated at 120V up to 460V did not have sufficient work space about them and were not readily accessible in an emergency situation due to being blocked by a work bench and spare materials, observed on or about 4/16/15.    b)9000 River Rd, Delair, NJ- Fabrication Machine Shop, Individual Equipment Disconnect Section: Electrical panel boxes including but not limited to panels rated at 120V up to 460V did not have sufficient work space about them and were not readily accessible in an emergency situation due to being blocked by a work bench and spare materials, observed on or about 4/16/15.    c)900 River Rd, Delair, NJ- Foundry, Furnace Electrical Controls: Electrical panel boxes including but not limited to panels rated at 120V up to 460V did not have sufficient work space about them and were not readily accessible in an emergency situation due to being blocked by a work bench and spare materials, observed on or about 4/16/15.    NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.303 G01 II

Serious Gravity 5 3 instances 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:    a)9000 River Rd, Delair, NJ- Billet Saw number 2:  460V electrical panel boxes did not have sufficient work space about them and were not readily accessible in an emergency situation due to being blocked by items including but not limited to cardboard, containers, chemicals, and spare parts, observed on or about 4/16/15.    a)9000 River Rd, Delair, NJ- Building 11, Upper Level of Fabrication Area: 460V electrical panel boxes did not have sufficient work space about them and were not readily accessible in an emergency situation due to being blocked by a shelving unit full of parts, observed on or about 4/16/15.    c)9000 River Rd, Delair, NJ- Building 10, Lower Vault, Danieli Press:  460V electrical panel boxes did not have sufficient work space about them and were not readily accessible in an emergency situation due to being blocked by items including but not limited to cardboard, containers, chemicals, and spare parts, observed on or about 4/16/15.    NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.304 F01 IV

Serious Gravity 5 4 instances 11 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel and were located in the vicinity of easily ignitable material:    a)9000 River Rd, Delair, NJ- Billet Saw number 2:  Electrical overcurrent devices did not have sufficient work space about them and were not readily accessible in an emergency situation due to being blocked by easily ignitable materials items including but not limited to cardboard, containers, chemicals, observed on or about 4/16/15.    b)9000 River Rd, Delair, NJ- Building 11, Upper Level of Fabrication Area: Electrical overcurrent devices did not have sufficient work space about them and were not readily accessible in an emergency situation due to being blocked by a shelving unit full of parts, observed on or about 4/16/15.    c)9000 River Rd, Delair, NJ- Building 10, Lower Vault, Danieli Press:  Electrical overcurrent devices were not readily accessible in an emergency situation due to being blocked by items including but not limited to cardboard, containers, chemicals, and parts, observed on or about 4/16/15.    d)9000 River Rd, Delair, NJ- Mold Maintenance:  Electrical overcurrent devices were not readily accessible in an emergency situation due to being blocked by items including but not limited to cardboard, containers, chemicals, and parts, observed on or about 4/16/15.    NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a)9000 River Rd, Delair, NJ- Foundry, Electrical Room: A 120V electrical panel box was live but not guarded against accidental contact where employees used a junction box as an extension cord, observed on or about 4/16/15.    NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.304 G05

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    a) 9000 River Rd, Delair, NJ- Building 4: The path to ground was not continuous on an industrial fan, model # MAC-42-320-3209-C7-J1, Serial #13618491, the ground pin was missing, observed on or about 5/13/2015.    b)9000 River Rd, Delair, NJ- Anodizing Area: The path to ground was not continuous on an industrial fan, model # MAC-42-320-3209-C7-J1, the ground pin was missing, observed on or about 5/13/2015.    NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.305 A02 X

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.305(a)(2)(x):  Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:    a)9000 River Rd, Delair, NJ- Foundry: A temporary power cord was used to power a vacuum cleaner and run underneath of a closed door to the foundry electrical room, observed on or about 4/16/15.    NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.305 G01 IV A

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Sep 22, 2015
Abate by
Oct 14, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  a)9000 River Rd, Delair, NJ- Saw House: flexible cords were used as a substitute for permanent wiring in the saw house to power a computer station, observed on or about 4/16/15.   NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.305 A02 IX

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lamp holder with a guard:    a)9000 River Rd, Delair, NJ- Building 11, Maintenance Area:  Overhead fluorescent light bulbs were not protected from accidental contact, observed on or about 4/16/15.    b)9000 River Rd, Delair, NJ- Dye Correction:  Overhead fluorescent light bulbs were not protected from accidental contact, observed on or about 4/16/15.    NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.305 E01

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures were not weatherproof in wet locations:    a)9000 River Rd, Delair, NJ, Billet Saw number 2, Outside: The control box that operates the conveyor on the exterior of the saw house was not weather proof and was wrapped with duct tape and a rain jacket, observed on or about 5/13/2015.       NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.305 J02 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location:    a)9000 River Rd, Delair, NJ, Anodizing: A duplex receptacle 110/120 volt, 20 amp was missing the waterproof enclosure and sealed with duct tape, observed on or about 5//13/15.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1030 C02 I A

Serious Gravity 5 1 instance 11 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.1030(c)(2)(i)(A): The exposure determination did not include a list of all job classifications in which all employees in those job classifications had occupational exposure:    a) Facility located at 9000 River Road, Delair, NJ: The employer failed to include designated first aid responders in their exposure determination, occurred on or about 5/13/2015.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2500
  • — C (S) $5000
  • — Z (S) $5000

1910.1030 F02 I

Serious Gravity 5 1 instance 11 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(f)(2)(i): Hepatitis B vaccination was not made available within 10 working days of initial assignment to all employee(s) with occupational exposure:    a) Facility located at 9000 River Road, Delair, NJ: The employer failed to offer the hepatitis B vaccination series to the designated first aid responders at the facility, occurred on or about 5/13/2015.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1030 G02 I

Serious Gravity 5 1 instance 11 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(g)(2)(i): The employer did not ensure that each employee with occupational exposure participated in a training program:    a) Facility located at 9000 River Road, Delair, NJ: The employer failed to provide a training program to the designated first aid responders at the facility, which included all the required elements of the standard. The training was provided by The Red Cross and did not address specific policies and procedures of the facility to include their post exposure control plan, occurred on or about 5/13/2015.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 B07 IV

Serious Gravity 5 6 instances 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $55,000 · Current $4,500 Reduced
29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.    a)9000 River Rd, Delair, NJ- Building 8, Philadelphia Tramrail, ID Number 1319: The pendant control box was split and missing sections it was wrapped with plastic wrap along the wire and down the top portion of the box, observed on or about 5/13/2015      b)9000 River Rd, Delair, NJ- Building 9, P&H 5 Ton, Number 994: The pendant control box case was damaged and was wrapped with black electrical tape around the top portion of the box, observed on or about 5/13/2015.    c)9000 River Rd, Delair, NJ- Building 4, P&H 5 ton crane, Id Number 2010: The pendant box was damaged. The lower portion of the back was pushed in and was wrapped with duct tape/ plastic wrap and the rubber boots for the push buttons were missing, observed on or about 6/23/15.    d)900 River Rd, Delair, NJ- Building 4, P&H 10 ton crane, number 2011: The pendant control box was lacking strain relief where the drop cord met the box, observed on or about 4/23/2015.    e)9000 River Rd, Delair, NJ- Building 2, Number 218: The pendant control box was  missing the rubber boots over the controls, observed on or about 5/13/2015.      NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (S) $4500
  • — C (W) $55000
  • — Z (W) $55000

1910.179 G01 V

Repeat Gravity 5 3 instances 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $25,000 · Current $25,000
29 CFR 1910.179(g)(1)(v): Pendant control boxes were not clearly marked for identification of functions:      a)9000 River Rd, Delair, NJ- Building 1, P&H, 3 Ton, Number 178: The pendant control box was missing labels, observed on or about 5/13/2015.      b)9000 River Rd, Delair, NJ- Building 2,Number 218: The pendant control box was missing labels, observed on or about 5/13/2015.    c)9000 River Rd, Delair, NJ- Building 4, P&H 5 ton crane, Id Number 2010: The pendant box was missing labels, observed on or about 6/23/15.      Aluminum Shapes LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.179(g)(1)(v), which was contained in OSHA inspection number 315978676, citation number 1, item number 2 and was affirmed as a final order on 5/3/2012, with respect to a workplace located at 9000 River Road, Delair, New Jersey.      NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (R) $25000
  • — C (R) $25000
  • — Z (R) $25000

1910.184 C01

Repeat Gravity 5 3 instances 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $25,000 · Current $25,000
29 CFR 1910.184(c)(1): Sling(s) that were damaged or defective were used:    a)9000 River Rd, Delair, NJ- Building 8, Crane 1319, Shipping Area: Employees lifting bundles of finished aluminum product were using Liftall slings which had been damaged sling# 304515-6 had a tear down the center which was approximately 4 inches in length and the center thread was broken, sling # 304515-7 contained a two inch hole  towards the upper portion of the gray padded area, and an approximate 8 inch split down the center on the other side of the padded area, or about 4/16/15.    b)9000 River Rd, Delair, NJ- Building 4, Crane 2010, Extrusion Area: Employees lifting bundles of finished aluminum product were using Liftall slings which had been compromised to the point of showing red indicator thread, the edging threads were ripped, there was a hole the through to the other side approximatley2 3/4 inches in size, and the eyelet was ripped, observed on or about 6/23/15.    c)9000 River Rd, Delair, NJ- Building 4, Crane 2009, Shipping Area: Employees lifting bundles of finished aluminum product were using Liftall slings which had been compromised to the point of showing red indicator threads, there was dime sized hole on the side of the yellow stripe which led through to a larger hole, approximate size of a quarter, observed on or about 6/23/15.    Aluminum Shapes LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.184(c)(1), which was contained in OSHA inspection number 315978676, citation number 1, item number 3(a) and was affirmed as a final order on 5/3/2012, with respect to a workplace located at 9000 River Road, Delair, New Jersey.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (R) $25000
  • — C (R) $25000
  • — Z (R) $25000

1910.184 I09 III

Repeat Gravity 5 3 instances 4 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.184(i)(9)(iii): Synthetic web sling(s) with snags, punctures, tears, or cuts were not immediately removed from service:    a)9000 River Rd, Delair, NJ- Building 8, Crane 1319, Shipping Area: Employees lifting bundles of finished aluminum product were using Liftall slings which had been damaged sling# 304515-6 had a tear down the center which was approximately 4 inches in length and the center thread was broken, sling # 304515-7 contained a two inch hole  towards the upper portion of the gray padded area, and an approximate 8 inch split down the center on the other side of the padded area, or about 4/16/15.    b)9000 River Rd, Delair, NJ- Building 4, Crane 2010, Extrusion Area: Employees lifting bundles of finished aluminum product were using Liftall slings which had been compromised to the point of showing red indicator thread, the edging threads were ripped, there was a hole the through to the other side approximatley2 3/4 inches in size, and the eyelet was ripped, observed on or about 6/23/15.    c)9000 River Rd, Delair, NJ- Building 4, Crane 2009, Shipping Area: Employees lifting bundles of finished aluminum product were using Liftall slings which had been compromised to the point of showing red indicator threads, there was dime sized hole on the side of the yellow stripe which led through to a larger hole, approximate size of a quarter, observed on or about 6/23/15.    Aluminum Shapes LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.184(i)(9)(iii), which was contained in OSHA inspection number 315978676, citation number 1, item number 3(c) and was affirmed as a final order on 5/3/2012, with respect to a workplace located at 9000 River Road, Delair, New Jersey.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (R) $0
  • — C (R) $0
  • — Z (R) $0

1910.212 A03 II

Repeat Gravity 5 5 instances 6 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $25,000 · Current $25,000
29 CFR 1910.212(a)(3)(ii): The  point of operation of machines whose operation exposed an employee to injury, was not guarded:    a) 9000 River Rd Delair, NJ- Building 1, Fabrication Area : Employees operating a metal cutoff saw (machine 888) to cut materials such as but not limited to aluminum were exposed to amputation hazards created by unguarded saw blades, occurred on or about 5/13/15.    b) 9000 River Rd Delair, NJ- Building 1, Fabrication Area : Employees operating a metal cutoff saw (machine 937) to cut materials such as but not limited to aluminum were exposed to amputation hazards created by unguarded saw blades, occurred on or about 5/13/15.    c) 9000 River Rd Delair, NJ- Building 1, Fabrication Area : Employees operating a metal cutoff saw (machine 117) to cut materials such as but not limited to aluminum were exposed to amputation hazards created by unguarded saw blades, occurred on or about 5/13/15.    d) 9000 River Rd, Delair, NJ- Building 11, Fabrication Area:  Employees operated a table saw (machine number 2063) to cut materials such as but not limited to plastic where guards were not present to prevent having any part of their body in the danger zone, occurred on or about 4/16/15.    e) 9000 River Rd, Delair, NJ- Building 1, Fabrication Machine Shop:  Employees operated a Do-All band saw to cut materials such as but not limited to metal where guards were not present to prevent having any part of their body in the danger zone, occurred on or about 4/16/15.    Aluminum Shapes LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.212(a)(3)(ii), which was contained in OSHA inspection number 315978676, citation number 1, item number 4 and was affirmed as a final order on 5/3/2012, with respect to a workplace located at 9000 River Road, Delair, New Jersey.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — J (R) $25000
  • — C (R) $25000
  • — Z (R) $25000

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
Sep 22, 2015
Penalty
Initial $5,000 · Current $5,000
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours:  a) Located at Aluminum Shapes LLC 9000 River Rd, Delair, NJ: On or about 3/24/15, an employee received an injury to his leg resulting in a hospitalization. The employer did not report the hospitalization of an employee to OSHA within 24 hours.  NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (O) $5000
  • — C (O) $5000
  • — Z (O) $5000

1910.134 C02 I

Other-than-serious 2 instances 2 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:    a) Facility located at 9000 River Road, Pennsauken NJ, Foundry: Appendix D was not provided to employees who were given N95 respirators to use while in the foundry, occurred on or about 5/13/2015.    b) Facility located at 9000 River Road, Pennsauken NJ, Foundry: Appendix D was not provided to employees who were given N95 respirators to use while in the annodizing area, occurred on or about 5/13/2015.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    (a) Facility located at 9000 River Road, Delair, NJ: Aluminum Shapes did not implement a hazard communication program which included procedures for informing contractors of the chemical hazards on site and ensure the labeling of chemicals removed from their original container, occurred on or about 5/13/2015.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.1200 E02

Other-than-serious 1 instance 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(2): The employer that produced, used, or stored hazardous chemicals at the workplace in such a way that employees of other employer(s) could be exposed did not ensure that the hazard communication program included all of the elements outlined in 29 CFR 1910.1200(e)(2)(i) through 29 CFR 1910.1200(e)(2)(iii): (Construction Reference: 1926.59)     (a) Facility located at 9000 River Road, Delair, NJ: Aluminum Shapes hazard communication program did not include the methods that would be used to communicate that hazards associated with the chemicals such as but not limited to ammonia, aluminum dust, silica, manganese, boron, graphite, and sulfuric acid at the facility to the contractors working onsite, occurred on or about 5/13/2015.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.1200 F08

Other-than-serious 2 instances 3 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(8): The employer did not label portable containers into which hazardous chemicals were transferred.    a) 9000 River Rd, Delair, NJ, #2 Billet Saw House: A white spray bottle containing a green liquid was not marked with it's contents, observed on or about 5/13/205.    b) 9000 River Rd, Delair, NJ, Waste Building: A white spray bottle containing a light blue liquid was not marked with its contents, observed on or about 5/13/205.      NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.1200 H03 IV

Other-than-serious 1 instance 4 exposed
Issued
Sep 22, 2015
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(iv):   The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information:    a)9000 River Rd, Delair, NJ, Facility: Employees working with and around products including but not limited to, simple green, ammonia, aluminum dust, silica, manganese, boron, graphite, sodium hydroxide and sulfuric acid were not provided with training on the revised HCS label elements and the new format and types of information on each section of the safety data sheets (SDSs), occurred on or about 5/13/15.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

View Aluminum Shapes, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340593680.