OSHA Inspection: PRIME PRODUCTS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRIME PRODUCTS INC. in 407 E HWY 90, SCHULENBURG, TX 78956 (NAICS 326160). OSHA activity number 340593730.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Prime Products INC. — free Get an email when a new federal OSHA severe-injury report for Prime Products INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PRIME PRODUCTS INC.
Site address
407 E HWY 90
City
SCHULENBURG
State
TX
ZIP
78956
Mailing
601 SOUTH MAIN, SCHULENBURG, TX 78956
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326160
Employees
130
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 30, 2015
Abate by
Oct 7, 2015
Penalty
Initial $4,500 · Current $2,700 Reduced
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing for likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of open flame:  On or about April 29, 2015, and at times prior thereto, employees were exposed to the hazards of open, unshielded natural gas fueled flames while operating the shop made bottle flame treating systems.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.147 D04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 30, 2015
Abate by
Oct 7, 2015
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  On or about April 29, 2015, and at times prior thereto, in the injection molding area, injection mold #2 was under repair or maintenance and had not been locked out and/or tagged by the authorized employees, exposing employees to the hazards of being struck by and/or caught in machines, or receiving electrical shock.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 30, 2015
Abate by
Oct 7, 2015
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  On or about April 29, 2015, and at times prior thereto, in the maintenance shop on the Baldor bench grinder the left side, the work rest opening exceeded one eighth inch, exposing employees to the hazards of being struck by flying wheel fragments in the event of wheel breakage.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 30, 2015
Abate by
Oct 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  On or about April 29, 2015, and at times prior thereto, the distance between the abrasive wheel periphery(s) and the adjustable tongue at the top of the Baldor Bench Grinder exceeded one fourth inch, exposing employees to the hazards of being struck by flying wheel fragments in the event of wheel breakage.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 F03

Serious Gravity 5 4 instances 4 exposed
Issued
Sep 30, 2015
Abate by
Oct 7, 2015
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed:  On or about April, 29, 2015 , and at times prior thereto, the employer did not ensure that sprockets and chains on 4 bottle flame treating systems were enclosed, exposing employees to the hazard of being caught in the sprockets and chains.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 30, 2015
Abate by
Oct 7, 2015
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  On or about April 29, 2015, and at times prior thereto, a five receptacle surge protector, designed for short term use was used as permanent wiring to supply power to multiple devices used in the facility, exposing employees to the hazard of electrical shock.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.303 B07 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 30, 2015
Abate by
Oct 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:  On or about April 29, 2015, and at times prior thereto, in the grinder area on grinder #2, the power control box on/off switches were broken and recessed in the control box requiring that the employees put their fingers into the control box, exposing employees to the hazard of electrical shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 30, 2015
Abate by
Oct 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  On or about April 29, 2015, and at times prior thereto, the employer did not ensure cords and cables were connected to devices so that strain relief was provided, exposing employees to the hazards of electrical shock:  a. In the grinder area on grinder #2 had the electrical power cord was pulled from the control box.   b. In the heat treat area on flamer #2 had the electrical power cord was pulled from the power control box.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Prime Products INC.'s full OSHA safety record →