Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CASSON DUNCAN CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CASSON DUNCAN CONSTRUCTION, INC. in 4986 AMAROSA HEIGHTS, COLORADO SPRINGS, CO 80922 (NAICS 236220). OSHA activity number 340597319.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Casson Duncan Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Casson Duncan Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4986 AMAROSA HEIGHTS
City
COLORADO SPRINGS
State
CO
ZIP
80922
Mailing
13275 E. FREMONT PLACE, SUITE 310, CENTENNIAL, CO 80112
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.651 J02

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Jun 3, 2015
Abate by
Jun 11, 2015
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:  (a)  On or about April 23, 2015, Casson Duncan Construction Inc., as controlling employer, did not ensure that employees of Fountain Valley Electrical LLC, subcontractor, were protected from roll-in hazards in that the spoil pile was placed on the edge of the trench in which they were working.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (S) $0
  • — C (S) $1200
  • — Z (S) $1200

1926.651 K01

Other-than-serious 1 instance 2 exposed
Issued
Jun 3, 2015
Abate by
Jun 11, 2015
Penalty
Initial $0 · Current $500
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift:    (a)  On or about April 23, 2015, and at times prior, Casson Duncan Construction Inc., as controlling employer, did not ensure that employees of Fountain Valley Electrical LLC, subcontractor, were working in a safe trench by ensuring that Fountain Valley Electrical LLC had a competent person for excavation to inspect the excavations for potential cave-in or other hazardous conditions prior to the start of work.     Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (O) $500
  • — C (S) $0
  • — Z (S) $0

View Casson Duncan Construction, INC.'s full OSHA safety record →