MANSFIELD, LA —
OSHA Inspection: HENSLEY INDUSTRIES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of HENSLEY INDUSTRIES, INC. in 816 JENKINS STREET, MANSFIELD, LA 71052 (NAICS 331513). OSHA activity number 340608215.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HENSLEY INDUSTRIES, INC.
- Site address
- 816 JENKINS STREET
- City
- MANSFIELD
- State
- LA
- ZIP
- 71052
- Mailing
- 816 JENKINS STREET, MANSFIELD, LA 71052
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331513
- Employees
- 14
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Sep 18, 2015
- Penalty
- Initial $3,400 · Current $2,040 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about 5/5/2015, near the molding area, the employer allowed employees to operate a band saw to cut materials used in the molding area without a guard for the exposed but unused portion of the blade.
Recent events (2)
- — I (S) $2040
- — Z (S) $3400
1910.242 B
- Issued
- Sep 18, 2015
- Penalty
- Initial $2,550 · Current $2,550
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about 5/5/2015, in the molding area, the employer allowed employees to use compressed air to remove debris from molds and did not ensure that the pressure was reduced to below 30 p.s.i.
Recent events (2)
- — I (O) $2550
- — Z (S) $2550
1910.146 C01
- Issued
- Sep 18, 2015
- Abate by
- Oct 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: On or about 05/05/2015, in the foundry building located at 816 Jenkins Street in Mansfield, the employer allowed employees to conduct foundry operations and maintenance work and did not evaluate the workplace to determine if any spaces were permit-required confined spaces.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Hensley Industries, INC.
View Hensley Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331513)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340608215.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.