Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMUNEAL MANUFACTURING CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of AMUNEAL MANUFACTURING CORPORATION in 4507 PAUL STREET, PHILADELPHIA, PA 19124 (NAICS 321999). OSHA activity number 340609692.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Amuneal Manufacturing Corporation — free Get an email when a new federal OSHA severe-injury report for Amuneal Manufacturing Corporation is published. One employer, no account, unsubscribe in one click.
Site address
4507 PAUL STREET
City
PHILADELPHIA
State
PA
ZIP
19124
Mailing
4737 DARRAH ST, PHILADELPHIA, PA 19124
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321999
Employees
120
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 3 instances 11 exposed
Issued
Nov 4, 2015
Abate by
Feb 8, 2016
Penalty
Initial $6,300 · Current $4,095 Reduced

Hazardous substances E200W103

OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion hazards due to deficient design and/or implementation of preventive and/or protective measures in its dust collection system and related equipment, such as the following:      Amuneal workshop located at 4507 Paul Street, Philadelphia, PA - Two enclosureless Nederman S Series Bag Filters, a Model S-1000 with a suction capacity of 4,000-5,000 cubic feet per minute (cfm) located in the rough mill and a Model S-750 with a suction capacity of 2,400-4,500 cfm located in the fabrication area, which handled Class II wood dust, were located inside the building and:    a) The dust collectors were located within 20 feet of employee work stations and main aisle ways. The collected dust was not removed daily or more frequently if necessary. The fan motors were not totally enclosed fan cooled design.   The collector was used for dust pick up other than wood; dust collected included metal shavings.  Condition noted on or about 8/13/15.        Abatement Note: Among other methods, one feasible and acceptable abatement method to correct the hazard is to ensure that dust collectors which are used indoors comply with NFPA 664 (2012) Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities.      In accordance with NFPA 664, Chapter 8, Section 8.2.2.5.1.4 (7) the criteria that need to be met in order to allow an enclosureless dust collector indoors are:    1) The collector is used only for dust pickup from wood processing machinery;  2) The collector is not used on sanders or abrasive planners having mechanical material feeds;   3) The fan motor is totally enclosed, fan-cooled design;   4) The collected dust is removed daily or more frequently if necessary to ensure efficient operation;   5) The collector is located at least 20 ft. from any means of egress or area routinely occupied by personnel {Note Per NFPA 101 Life Safety Code -The means of egress consists of exit routes, the exit door, and the public way (i.e. safe zone outside the building}   6) Multiple collectors in the same room are separated from each other by at least 20 ft.   7) Collector cannot exceed a maximum air handling capacity of 5,000 CFM.    **NOTE** all the criteria must meet.        b) Amuneal workshop located at 4507 Paul Street, Philadelphia, PA - The employer did not establish and implement a comprehensive inspection, testing, and maintenance program of the dust collection systems.  Condition noted on or about 8/13/15.    Abatement Note:  Among other methods, one feasible and acceptable abatement method to correct the hazard is to comply with relevant provisions in NFPA 664 (2012) Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities, such as:    Section 10.2 of NFPA 664 (2012) requires that an inspection, testing, and maintenance program be developed and implemented to ensure that the fire and explosion protection systems and related process controls and equipment perform as designed and Section 10.3 of NFPA 664 (2012) requires that records be kept of maintenance and repairs performed.       c) Amuneal workshop located 4507 Paul Street, Philadelphia, PA - Surfaces of planers, saws and other woodworking equipment were cleaned by blowing down with compressed air.  Observed on or about 5/5/15.    Abatement Note:  Among other methods, one feasible and acceptable abatement method to correct this hazard is to comply with relevant provisions in NFPA 664 (2012) Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities, such as:       Section 11.2.1.3 of 2012 NFPA 664 requires that surfaces are cleaned in a manner that minimizes the generation of dust clouds and is permitted only if the following requirements are met:    1.  The surfaces shall be vacuumed prior to blowdown.    2.  Electrical power and other sources of ignition shall be shut down  3.  Only a low gauge pressure of 15 psi compressed air shall be used  4.  No open flames, sparks from spark-producing equipment, or hot surfaces shall exist, and   5.  All fire protection equipment shall be in service.
Recent events (2)
  • — I (S) $4095
  • — Z (S) $6300

1910.1200 F05

Serious Gravity 5 2 instances 11 exposed
Issued
Nov 4, 2015
Abate by
Feb 8, 2016
Penalty
Initial $4,500 · Current $2,925 Reduced

Hazardous substances 0515

29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein:    a) Amuneal, 4507 Paul Street, Philadelphia, PA - Secondary containers containing Lye diluted with peroxide were unlabeled and not marked with appropriate hazard warnings regarding the chemicals contained therein.  Observed on or about 5/5/15.
Recent events (2)
  • — I (S) $2925
  • — Z (S) $4500

1910.1200 H01

Serious Gravity 5 1 instance 11 exposed
Issued
Nov 4, 2015
Penalty
Initial $5,400 · Current $0 Reduced

Hazardous substances W103

29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    a)  Amuneal, 4507 Paul Street, Philadelphia, PA, Rough Mill and Fabrication Area(s):  Employees were not provided information and training on the hazards of combustible dust.  Condition noted on or about 8/13/15.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5400

1910.134 E01

Repeat Gravity 5 2 instances 4 exposed
Issued
Nov 4, 2015
Abate by
Feb 8, 2016
Penalty
Initial $10,800 · Current $7,020 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    (a) Amuneal, 4507 Paul Street, Philadelphia, PA.  Employees conducting buffing and grinding operations, including the use of the pedestal grinder,  were required to wear a respirator including, but not limited to, 3M 8511 particulate respirator, without a medical evaluation.  Condition noted on or about 5/5/15.    Amuneal Manufacturing Corp. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 837803, citation number 1, item number 1b and was affirmed as a final order on July 18, 2013 with respect to a workplace located at 4737 Darrah Street, Philadelphia, PA.
Recent events (2)
  • — I (R) $7020
  • — Z (R) $10800

1910.134 F02

Serious Gravity 5 2 instances 4 exposed
Issued
Nov 4, 2015
Abate by
Dec 23, 2015
Penalty
Initial $5,400 · Current $0 Reduced
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:     a) Amuneal, 4507 Paul Street, Philadelphia, PA - Employees assigned to fabrication area were not fit tested prior to initial use of tight-fitting respirators including, but not limited to, North 7700 series with 75 FFP100 filters and MSA Advantage series GMA P100/ov cartridges, when performing spray finishing operations.  Condition noted on or about 5/5/15.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5400

1910.134 K01

Serious Gravity 5 1 instance 9 exposed
Issued
Nov 4, 2015
Abate by
Jan 31, 2016
Penalty
Initial $5,400 · Current $0 Reduced
29 CFR 1910.134(k)(1): The Employer did not ensure that employees were provided with effective training when employees use respirators, and did not ensure that employees could demonstrate knowledge as required in (k)(1)(i)-(k)(1)(vii):     a) Amuneal, 4507 Paul Street, Philadelphia, PA - Grinding to include pedestal grinder and Spray Finishing Areas: Employees, who were required to wear respirators such as, but not limited to N95 filtering face-piece respirators with exhalation valve (3M 8511), and/or tight-fitting elastomeric respirators such as, but not limited to, MSA Advantage series with GMA P100/OV cartridges, North 7700 series with 75FFP100 cartridges, etc.  were not provided with effective respirator training.  The Employer did not ensure that employees could demonstrate knowledge as required in (k)(1)(i)-(k)(1)(vii).       Condition noted on/or about 5/5/15.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5400

View Amuneal Manufacturing Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340609692.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.