MACON, GA —
OSHA Inspection: CALIFORNIA CEREAL PRODUCTS, INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of CALIFORNIA CEREAL PRODUCTS, INC. in 4375 MEAD RD., MACON, GA 31206 (NAICS 311230). OSHA activity number 340610914.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CALIFORNIA CEREAL PRODUCTS, INC.
- Site address
- 4375 MEAD RD.
- City
- MACON
- State
- GA
- ZIP
- 31206
- Mailing
- 4375 MEAD RD., MACON, GA 31206
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311230
- Employees
- 125
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II C
- Issued
- Sep 3, 2015
- Abate by
- Dec 7, 2015
- Penalty
- Initial $4,950 · Current $2,475 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. 1) On or about May 6, 2015 the energy control procedures did not include verification steps to be carried out when incoming operators took over locked equipment: a. Cookers - electrical, pneumatic, and steam energy sources b. Jet Zone - electrical, pneumatic, and steam energy sources c. Dryer (Mill Area) - electrical, pneumatic, and gravity energy sources d. Upper Mill Equipment - electrical, pneumatic, and mechanical energy sources
Recent events (2)
- — I (O) $2475
- — Z (S) $4950
1910.147 C04 II B
- Issued
- Sep 3, 2015
- Abate by
- Dec 7, 2015
- Penalty
- Initial $9,900 · Current $4,950 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down machines or equipment to control hazardous energy. 1) On or about May 6, 2015 the energy control procedures did not include shutdown steps as part of the written lockout procedures a. Cookers - electrical, pneumatic, and steam energy sources b. Jet Zone - electrical, pneumatic, and steam energy sources c. Dryer (Mill Area) - electrical, pneumatic, and gravity energy sources d. Upper Mill Equipment - electrical, pneumatic, and mechanical energy sources
Recent events (2)
- — I (S) $4950
- — Z (R) $9900
More inspections at California Cereal Products, INC.
View California Cereal Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311230)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340610914.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.