OSHA Inspection: TIMKENSTEEL CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TIMKENSTEEL CORPORATION in GAMBRINUS PLANT 2401 GAMBRINUS AVE, CANTON, OH 44706 (NAICS 331110). OSHA activity number 340624634.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Timkensteel Corporation — free Get an email when a new federal OSHA severe-injury report for Timkensteel Corporation is published. One employer, no account, unsubscribe in one click.
Site address
GAMBRINUS PLANT 2401 GAMBRINUS AVE
City
CANTON
State
OH
ZIP
44706
Mailing
1835 DUEBER AVE, CANTON, OH 44706
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331110
Employees
600
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Oct 29, 2015
Abate by
Nov 13, 2015
Penalty
Initial $7,000 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that they were exposed to crushing and struck by hazards:  On or about May 1, 2015, employees were exposed to crushing and struck by hazards while loading/unloading the guides on the Sutton 3-2 Roll Straightener in that employees stand in the drop zone and the drop chain does not have a safety latch on the hook.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.132 C

Deleted Serious Gravity 10 2 instances 20 exposed
Issued
Oct 29, 2015
Abate by
Dec 3, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.132(c): Personal protective equipment was not of safe design and construction for the work to be performed:  a. On or about August 15, 2015, the employer failed to ensure employees performing monthly preventive maintenance on the 84 crane were protected against a fall of approximately 40 feet by utilizing certified, designed tie off points. Employees tie off to whatever they feel will hold them.   b. On or about August 15, 2015, the employer failed to ensure employees performing monthly preventive maintenance on the 60 crane were protected against a fall of approximately 40 feet by utilizing certified, designed tie off points. Employees tie off to whatever they feel will hold them.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.23 C03

Repeat Gravity 10 1 instance 5 exposed
Issued
Oct 29, 2015
Penalty
Initial $70,000 · Current $70,000
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board:    On or about May 1, 2015, the employer failed to ensure employees performing guide changes on the Sutton 3-2 Roll Straightener were protected against a fall of 3 feet into a slew way hole/pit. The pit is filled with sludge, coolant and sharp broken steel shards.
Recent events (3)
  • — F (R) $70000
  • — C (W) $70000
  • — Z (W) $70000

1910.147 C04 I

Deleted Repeat Gravity 10 1 instance 5 exposed
Issued
Oct 29, 2015
Penalty
Initial $38,500 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about May 1, 2015, the employer failed to ensure written procedures for the guide change on the Sutton 3-2 Roll Straightener were developed and utilized by operators. Operators climb into the machine only utilizing the emergency stop and hydraulics on/off button.   The TimkenSteel Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(4)(i), which was contained in OSHA inspection number 971450, citation number 01, item number 004A and was affirmed as a final order on August 7, 2014, with respect to a workplace located at 4511 Faircrest Ave. SW, Canton, OH 44706.
Recent events (3)
  • — F (R) $0
  • — C (R) $38500
  • — Z (R) $38500

1910.147 D04 I

Deleted Repeat Gravity 10 1 instance 5 exposed
Issued
Oct 29, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  On or about May 1, 2015, the employer failed to ensure employees changing guides on the Sutton 3-2 Roll Straightener  affixed a lock to energy isolating devices for electrical, hydraulic, rolling stock, and pneumatic power sources.  The TimkenSteel Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(d)(4)(i), which was contained in OSHA inspection number 971450, citation number 01, item number 004B and was affirmed as a final order on August 7, 2014, with respect to a workplace located at 4511 Faircrest Ave. SW, Canton, OH 44706.
Recent events (3)
  • — F (R) $0
  • — C (R) $0
  • — Z (R) $0

View Timkensteel Corporation's full OSHA safety record →