Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UHL CONSTRUCTION COMPANY INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UHL CONSTRUCTION COMPANY INC. in 4890 GRAND AVENUE, NEVILLE ISLAND, PA 15225 (NAICS 236210). OSHA activity number 340628445.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch UHL Construction Company INC. — free Get an email when a new federal OSHA severe-injury report for UHL Construction Company INC. is published. One employer, no account, unsubscribe in one click.
Site address
4890 GRAND AVENUE
City
NEVILLE ISLAND
State
PA
ZIP
15225
Mailing
P.O. BOX 8, ALLISON PARK, PA 15101
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
11
Ownership type
A

2 citations on file for this inspection.

1926.760 C03

Serious Gravity 5 1 instance 6 exposed
Issued
May 22, 2015
Abate by
May 29, 2015
Penalty
Initial $3,500 · Current $2,345 Reduced
29 CFR 1926.760(c)(3): The boundaries of the controlled decking zone were not marked.     (a) Jobsite, Roof:  On or about May 12, 2015, six employees were installing roof panels on the roof and the controlled decking zone was not marked.
Recent events (2)
  • — I (S) $2345
  • — Z (S) $3500

1926.760 B03

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
May 22, 2015
Abate by
May 29, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.760(b)(3): Each connector working at heights over 15 and up to 30 feet above a lower level, was not provided with a personal fall arrest system, positioning device system or fall restraint system and wear the equipment necessary to be able to be tied off; or was not provided with other means of protection from fall hazards in accordance with paragraph (a)(1) of this section:  (a) Jobsite, Roof:  On or about May 12, 2015, the six employees working from the roof installing roof panels were not provided with a personal fall arrest system, fall restraint system, or any other means of protection from fall hazards.  This fall protection equipment was not on the site let alone installed and available for use on the roof.  The fall hazard to the employees ranged from 24 feet to 25 feet 10 inches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View UHL Construction Company INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340628445.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.