MARKHAM, IL —
OSHA Inspection: K-FIVE CONSTRUCTION CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of K-FIVE CONSTRUCTION CORPORATION in 16222 S. WESTERN AVE., MARKHAM, IL 60426 (NAICS 324121). OSHA activity number 340628650.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- K-FIVE CONSTRUCTION CORPORATION
- Site address
- 16222 S. WESTERN AVE.
- City
- MARKHAM
- State
- IL
- ZIP
- 60426
- Mailing
- 13769 MAIN STREET, LEMONT, IL 60439
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 324121
- Employees
- 350
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 E01
- Issued
- Jun 19, 2015
- Penalty
- Initial $5,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.23(e)(1): A standard railing shall consist of top rail, intermediate rail, and posts, and shall have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level. The top rail shall be smooth-surfaced throughout the length of the railing. The intermediate rail shall be approximately halfway between the top rail and the floor, platform, runway, or ramp. The ends of the rails shall not overhang the terminal posts except where such overhang does not constitute a projection hazard. a. On or about May 13, 2015, at the above located workplace, an employee accessed a platform atop of the Prime Tank to check fluid levels. The top rail of the platform was below (29 inches) the minimum vertical height of 42 inches, thereby exposing the employee to fall hazards.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
1910.146 D03 III
- Issued
- Jun 19, 2015
- Abate by
- Sep 17, 2015
- Penalty
- Initial $5,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.146(d)(3)(iii): Under the permit space program required by paragraph (c)(4) of this section, the employer shall develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including, but not limited to, isolating the permit space: a) On or about March 18, 2015, at the above located workplace, employees entered the dryer, which is a permit required confined space, to perform oxy-fuel cutting and welding operations. The employer did not isolate the Dryer from the hazards posed by the presence of natural gas during an authorized entry for maintenance, thereby exposing employees to atmospheric and fire hazards.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
1910.146 D03 IV
- Issued
- Jun 19, 2015
- Abate by
- Jul 16, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(d)(3)(iii): Under the permit space program required by paragraph (c)(4) of this section, the employer shall develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including, purging, inerting, flushing, or ventilating the permit space as necessary to eliminate or control atmospheric hazards: a) On or about March 18, 2015, at the above located workplace, employees entered the dryer, which is a permit required confined space, to perform oxy-fuel cutting and welding operations. The employer did not purge or ventilate the space posed by the potential presence of natural gas during an authorized entry for maintenance, thereby exposing employees to atmospheric and fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 F08
- Issued
- Jun 19, 2015
- Abate by
- Sep 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(f)(8): The entry permit that documents compliance with this section and authorizes entry to a permit space shall identify the measures used to isolate the permit space and to eliminate or control permit space hazards before entry: a) On or about March 18, 2015, at the above located workplace, employees entered the dryer, which is a permit required confined space, to perform oxy-fuel cutting and welding operations. The employer had completed a confined space entry permit(s) that did not accurately reflect the status of the space having been isolated from other operations, thereby exposing employees to atmospheric and fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 G04
- Issued
- Jun 19, 2015
- Abate by
- Sep 17, 2015
- Penalty
- Initial $5,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.146(g)(1): The employer shall provide training so that all employees whose work is regulated by this section acquire the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under this section: a) On or about March 18, 2015, at the above located workplace, employees entered the dryer, a permit required confined space, to perform oxy-fuel cutting and welding operations. The employer had not provided authorized employees with effective training, including isolation of the natural gas line prior to entry, thereby exposing employees to atmospheric and fire hazards.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
1910.253 B04 III
- Issued
- Jun 19, 2015
- Abate by
- Jul 16, 2015
- Penalty
- Initial $5,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a. On or about May 15, 2015, at the above located workplace, compressed oxygen cylinders were stored near the flammable gas cylinders. The oxygen cylinders were not separated a minimum of 20 feet from the flammable compressed gas cylinders or by a noncombustible barrier at least 5 foot high, thereby exposing employees to fire hazards.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
More inspections at K-Five Construction Corporation
View K-Five Construction Corporation's full OSHA safety record →
More inspections in this industry (NAICS 324121)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340628650.