JUDA, WI —
OSHA Inspection: GRANDE CHEESE COMPANY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GRANDE CHEESE COMPANY in N2607 COUNTY HIGHWAY S, JUDA, WI 53550 (NAICS 311513). OSHA activity number 340632355.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GRANDE CHEESE COMPANY
- Site address
- N2607 COUNTY HIGHWAY S
- City
- JUDA
- State
- WI
- ZIP
- 53550
- Mailing
- P.O. BOX 67, BROWNSVILLE, WI 53006
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311513
- Employees
- 105
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.24 B
- Issued
- Nov 9, 2015
- Abate by
- Apr 30, 2016
- Penalty
- Initial $4,250 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.24(b): Fixed stairs were not provided were access to elevations was daily or at each shift for such purposes as gauging, inspection, regular maintenance, etc., where such work may expose employee(s) to acids, caustics, gases, or other harmful substances, or for which purposes the carrying of tools or equipment by hand is normally required: Fixed stairs were not provided for access to the rooftop located ammonia refrigeration system equipment, included but not limited to, evaporative condensers, piping, and pressure relief valves, which required daily inspection and regular maintenance, and may expose workers to ammonia gas.
Recent events (2)
- — I (O) $2550
- — Z (S) $4250
1910.119 D03 I E
- Issued
- Nov 9, 2015
- Abate by
- Dec 2, 2015
- Penalty
- Initial $4,250 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(i)(E): Ventilation system design;
Recent events (2)
- — I (S) $2550
- — Z (S) $4250
1910.119 D03 II
- Issued
- Nov 9, 2015
- Abate by
- Dec 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices. The employer did not document that the ammonia refrigeration equipment complies with recognized and generally accepted good engineering practices, including, but not limited to, the following: b) The employer did not ensure that a daily log was taken of the operating conditions of the ammonia system. (IIAR Bulletin 110) c) Signage was not present to indicate the meaning of each ammonia detector alarm. (ANSI/IIAR-2-2008) d) Roof top vents from the relief headers in the engine room exhaust downwards toward catwalks and ladders to the evaporative condensers. (ANSI/IIAR-2-2008) e) The brine chiller had extensive corrosion present and damaged insulation that was not repaired and corrected. (IIAR Bulletin 110) f) The glycol chiller had extensive corrosion present and damaged insulation that was not repaired and corrected. (IIAR Bulletin 110)
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.119 E01
- Issued
- Nov 9, 2015
- Abate by
- Dec 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(e)(1): The employer did not perform an initial process hazard analysis (hazard evaluation) on processes covered by 29 CFR 1910.119: The employer did not perform an initial process hazard analysis of the ammonia refrigeration system.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.119 F01
- Issued
- Nov 9, 2015
- Abate by
- Dec 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(f)(1): 29 CFR 1910.119(f)(1): The employer did not develop and implement written operating procedures that provided clear instructions for safely conducting activities involved in each covered process consistent the safety information and which address the elements listed in 29 CFR 1910.119(f)(1)(i) through (f)(1)(v): The employer did not develop written operating procedures for the operation of the ammonia refrigeration system.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.119 G01 I
- Issued
- Nov 9, 2015
- Abate by
- Dec 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(g)(1)(i): 29 CFR 1910.119(g)(1)(i): The employer did not train each employee involved in the operating process, in a overview of the process and in the operating procedures as specified in paragraph (f) of 29 CFR 1910.119: The employer did not train employees in the operating procedures as specified in paragraph (f) of 29 CFR 1910.119 for the ammonia refrigeration system.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.119 I02 IV
- Issued
- Nov 9, 2015
- Abate by
- Dec 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(i)(2)(iv): Training of each employee involved in operating a process has been completed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.119 J02
- Issued
- Nov 9, 2015
- Abate by
- Mar 31, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish or implement written procedures to maintain the on-going integrity of process equipment: The employer did not establish written procedures to maintain the on-going integrity of the ammonia refrigeration system.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.119 L01
- Issued
- Nov 9, 2015
- Abate by
- Dec 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(l)(1): The employer did not establish and implement written procedures to manage changes to process chemicals, technology, equipment, and procedures; and, changes to facilities that affect a covered process. The employer did not establish written procedures to manage changes to the ammonia refrigeration system, including but not limited to, standard operating procedure changes, mechanical integrity procedure changes, and P&ID changes.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Grande Cheese Company
View Grande Cheese Company's full OSHA safety record →
More inspections in this industry (NAICS 311513)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340632355.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.