OSHA Inspection: LEGACY CONVERTING INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of LEGACY CONVERTING INC. in 3 SECURITY DRIVE, SUITE 301, CRANBURY, NJ 08512 (NAICS 322299). OSHA activity number 340633650.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Legacy Converting INC. — free Get an email when a new federal OSHA severe-injury report for Legacy Converting INC. is published. One employer, no account, unsubscribe in one click.
Site address
3 SECURITY DRIVE, SUITE 301
City
CRANBURY
State
NJ
ZIP
08512
Mailing
3 SECURITY DRIVE, SUITE 301, CRANBURY, NJ 08512
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322299
Employees
22
Ownership type
A

4 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 12, 2015
Abate by
Dec 17, 2015
Penalty
Initial $2,000 · Current $1,300 Reduced

Hazardous substances 8111

29 CFR 1910.95(c)(1): A continuing, effective hearing conservation program as described in 29 CFR 1910.95( c) through (n ) was not instituted when employee noise exposures equaled or exceeded an 8 hour time weighted average sound level (TWA) of 85dBA:            Legacy Converting, Inc / Cranbury NJ: The Employer did not provide a continuing effective Hearing Conservation Program for employees exposed to noise above 85 dBA. Employees were exposed to continuous noise levels equivalent to 75.36%  (87.9 dbA) and 129.8% (91.8 dbA) respectively of the allowable dose of 50%, or 85 dBA for an 8-hour TWA. The levels are above the 8-hour TWA of 85dBA over 400 minutes. Zero exposure was assumed for all unsampled time periods.     Observed on or about 05/15/2015.
Recent events (2)
  • — I (S) $1300
  • — Z (S) $2000

1910.1200 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 12, 2015
Abate by
Dec 17, 2015
Penalty
Initial $1,600 · Current $1,040 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:            Legacy Converting Inc/ NJ site: A site specific written hazard communication program had not been developed and implemented at the facility where employee(s) use products including, but not limited to Ceram  Cleaning product, Super Tech GL5 80W90 Gear oil, and Klean Strip Lacquer thinner.    Condition observed on or about 05/15/2015.
Recent events (2)
  • — I (S) $1040
  • — Z (S) $1600

1910.1200 H01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 12, 2015
Abate by
Dec 17, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employers were not provided information and training as specified in 29 CFR 1910.1200(h)(2) and (3) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area:          Legacy Converting, Inc/ NJ site: Employees exposed to chemicals which include, but not limited to Ceram Clean II product, Super Tech GL5 80W90 Gear oil, and Klean Strip lacquer thinner did not receive site specific training of the risks associated with products handled during cleaning/maintenance operations.   Observed on/or about 05/15/15.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Other-than-serious 2 instances 2 exposed
Issued
Nov 12, 2015
Abate by
Dec 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:   Legacy Converting, Inc. Cranbury, NJ Site: Portable fire extinguishers located on the Production floor were not mounted.   Observed on/or about 5/15/2015.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Legacy Converting INC.'s full OSHA safety record →