ERIE, PA —
OSHA Inspection: LATHROP ELECTRIC, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LATHROP ELECTRIC, INC. in 350 EAST 6TH STREET, ERIE, PA 16507 (NAICS 238210). OSHA activity number 340641331.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LATHROP ELECTRIC, INC.
- Site address
- 350 EAST 6TH STREET
- City
- ERIE
- State
- PA
- ZIP
- 16507
- Mailing
- 1104 SELINGER AVENUE, ERIE, PA 16505
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.300 A
- Issued
- Jul 8, 2015
- Abate by
- Aug 3, 2015
- Penalty
- Initial $2,100 · Current $1,155 Reduced
General-duty citation text
29 CFR 1926.300(a): Hand tool(s), power tool(s) or similar equipment were not maintained in a safe condition: A.) Lathrop Electric, Inc., 350 East 6th Street, Erie, PA 16507, first floor storage area, on or about May 14, 2015 and times prior thereto: The cord on the Ridgid Wet/Dry 16-gallon vacuum was frayed at the cord cap and near the termination into the vacuum.
Recent events (2)
- — I (S) $1155
- — Z (S) $2100
1926.20 B03
- Issued
- Jul 8, 2015
- Abate by
- Aug 3, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(3): Machinery, tool(s), material(s), or equipment which was not in compliance with the applicable requirement(s) of 29 CFR 1926 was not prohibited, and/or was not either identified as unsafe by tagging, or locking the controls to render them inoperable, or physically removed from its place of operation: A.) Lathrop Electric, Inc., 350 East 6th Street, Erie, PA 16507, first floor storage area, on or about May 14, 2015 and times prior thereto: The cord on the Ridgid Wet/Dry 16-gallon vacuum was frayed at the cord cap and near the termination into the vacuum. B.) Lathrop Electric, Inc., 350 East 6th Street, Erie, PA 16507, first floor storage area / gang box, on or about May 14, 2015 and times prior thereto: The outer jacket of a yellow flexible extension cord was frayed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.20 B02
- Issued
- Jul 8, 2015
- Abate by
- Aug 3, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): A.) Lathrop Electric, Inc., 350 East 6th Street, Erie, PA 16507, first floor storage area, on or about May 14, 2015 and times prior thereto: Electrical inspections of flexible cords and extension cords were not adequate to identify damage and defective parts as evidenced by: 1.) Electrical equipment included, but was not limited to, the flexible electrical cord on the Ridgid Wet/Dry 16-gallon vacuum. The flexible electrical cord was frayed at the cord cap and near the termination into the vacuum. 2.) Electrical equipment included, but was not limited to, a yellow flexible electrical extension cord was frayed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.403 B02
- Issued
- Jul 8, 2015
- Abate by
- Aug 3, 2015
- Penalty
- Initial $2,100 · Current $1,155 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: A.) Lathrop Electric, Inc., 350 East 6th Street, Erie, PA 16507, north interior stairwell, on or about May 14, 2015 and times prior thereto: Employee were utilizing a set of interior stairs on the north side of the structure to access upper and lower floors. A metal electrical knockout box was hanging in the stairwell area by non-metallic sheathed cable. The metal electrical knockout box was potentially exposed to physical damage and snaring in that the box was not secured and mounted.
Recent events (2)
- — I (S) $1155
- — Z (S) $2100
1926.403 B01
- Issued
- Jul 8, 2015
- Abate by
- Aug 3, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: A.) Lathrop Electric, Inc., 350 East 6th Street, Erie, PA 16507, north interior stairwell, on or about May 14, 2015 and times prior thereto: Employee were utilizing a set of interior stairs on the north side of the structure to access upper and lower floors. A metal electrical knockout box was hanging in the stairwell area by non-metallic sheathed cable. The metal electrical knockout box was potentially exposed to physical damage and snaring in that the box was not secured and mounted. B.) Lathrop Electric, Inc., 350 East 6th Street, Erie, PA 16507, north interior stairwell, on or about May 14, 2015 and times prior thereto: Employee were utilizing a set of interior stairs on the north side of the structure to access upper and lower floors. A metal electrical knockout box was hanging in the stairwell area by non-metallic sheathed cable. The non-metallic sheathed cable was potentially exposed to physical damage and snaring in that theType NM cable was not secured.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Lathrop Electric, INC.
View Lathrop Electric, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340641331.