MEDINA, OH —
OSHA Inspection: TFP CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TFP CORPORATION in 460 LAKE ROAD, MEDINA, OH 44256 (NAICS 332722). OSHA activity number 340648849.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TFP CORPORATION
- Site address
- 460 LAKE ROAD
- City
- MEDINA
- State
- OH
- ZIP
- 44256
- Mailing
- 460 LAKE ROAD, MEDINA, OH 44256
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332722
- Employees
- 150
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jun 30, 2015
- Abate by
- Sep 30, 2015
- Penalty
- Initial $6,300 · Current $4,410 Reduced
8870
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about May 21, 2015, the employer failed to ensure operators of the P&E Header number 20 utilized lockout/tagout procedures while performing tool changes.
Recent events (2)
- — I (S) $4410
- — Z (S) $6300
1910.147 C06 I
- Issued
- Jun 30, 2015
- Abate by
- Sep 30, 2015
- Penalty
- Initial $6,300 · Current $0 Reduced
8870
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about May 21, 2015, the employer failed to conduct annual audits to ensure the lockout/tagout procedure for the P&E Header Machine #20 was being followed and was updated as necessary.
Recent events (2)
- — I (S) $0
- — Z (S) $6300
1910.147 C07 I
- Issued
- Jun 30, 2015
- Abate by
- Aug 5, 2015
- Penalty
- Initial $6,300 · Current $4,410 Reduced
8870
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: On or about May 21, 2015, the employer failed to ensure employees cleaning and changing tooling on the P&E Header Machine #20 machinery were trained as authorized employees.
Recent events (2)
- — I (S) $4410
- — Z (S) $6300
1910.147 D04 I
- Issued
- Jun 30, 2015
- Abate by
- Aug 5, 2015
- Penalty
- Initial $6,300 · Current $0 Reduced
8870
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about May 21, 2015, the employer failed to ensure employees cleaning and changing tooling on the P&E Header Machine #20 machinery placed locks on all energy sources identified in the written procedures.
Recent events (2)
- — I (S) $0
- — Z (S) $6300
1910.179 J02 III
- Issued
- Jun 30, 2015
- Abate by
- Aug 31, 2015
- Penalty
- Initial $4,500 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, were not performed: On or about May 21, 2015, the employer failed to ensure certified hook inspections were performed and documented for all cranes such as but not limited to the Budgit 3 ton crane, serial number M55701 located in the Cold Header Assembly area.
Recent events (2)
- — I (S) $3150
- — Z (S) $4500
1910.179 J02 IV
- Issued
- Jun 30, 2015
- Abate by
- Aug 31, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed: On or about May 21, 2015, the employer failed to ensure certified wire rope inspections were performed and documented for all cranes such as but not limited to the Budgit 3 ton crane, serial number M55701 located in the Cold Header Assembly area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Jun 30, 2015
- Abate by
- Aug 5, 2015
- Penalty
- Initial $6,300 · Current $4,410 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by pinch points: On or about May 13, 2015, the employer failed to ensure employees operating the butt welder serial number 31516, model number H-X in the Cold Header Assembly area were protected against contact with the hold down clamps during operations.
Recent events (2)
- — I (S) $4410
- — Z (S) $6300
More inspections at TFP Corporation
View TFP Corporation's full OSHA safety record →
More inspections in this industry (NAICS 332722)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340648849.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.