OSHA Inspection: JT MARINE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JT MARINE, INC. in 2301 SE HIDDEN WAY STE 100, VANCOUVER, WA 98661 (NAICS 336611). OSHA activity number 340664788.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JT Marine, INC. — free Get an email when a new federal OSHA severe-injury report for JT Marine, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
JT MARINE, INC.
Site address
2301 SE HIDDEN WAY STE 100
City
VANCOUVER
State
WA
ZIP
98661
Mailing
2301 SE HIDDEN WAY STE 100, VANCOUVER, WA 98661
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
56
Ownership type
A

5 citations on file for this inspection.

1915.73 D

Other-than-serious 1 instance 5 exposed
Issued
Jul 20, 2015
Abate by
Aug 13, 2015
Penalty
Initial $3,500 · Current $3,500
29 CFR 1915.73(d): When employees were exposed to unguarded edges of decks, platforms, flats, or similar flat surfaces, more than 5 feet above a solid surface, the edges were not guarded by adequate guardrails meeting the requirements of 29 CFR 1915.71(j)(1) and (2).    Shaver Barge:  On or about May 27, 2015 and times prior thereto, the port and starboard edges of the weather deck did not have guardrails or other means to protect employees.  This exposed employees to approximately an 18 foot fall to the dry-dock floor.
Recent events (2)
  • — I (O) $3500
  • — Z (S) $3500

1915.73 B

Other-than-serious 1 instance 5 exposed
Issued
Jul 20, 2015
Abate by
Aug 13, 2015
Penalty
Initial $0 · Current $0
29 CFR 1915.73(b): When employees were working in the vicinity of flush manholes and other small openings of comparable size in the deck and other working surfaces, such openings were not suitably covered or guarded to a height of not less than 30 inches.    Shaver Barge:  On or about May 27, 2015 and times prior thereto, there were open flush manholes that were not guarded.  This exposed employees to a fall of 15 feet to the lower level.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1915.72 A03

Other-than-serious 1 instance 1 exposed
Issued
Jul 20, 2015
Abate by
Aug 13, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1915.72(a)(3): Portable ladders were not lashed, blocked, or otherwise secured to prevent their displacement and did not extend above the access point.    Lower stern section of barge:  On or about May 27, 2015 and times prior thereto, employee was using a ladder that was not lashed and did not extend above where he needed to access.  This exposed employee to a eight foot fall to dry-dock floor.
Recent events (2)
  • — I (O) $2800
  • — Z (S) $2800

1915.56 B04

Other-than-serious 1 instance 10 exposed
Issued
Jul 20, 2015
Abate by
Aug 13, 2015
Penalty
Initial $0 · Current $0
29 CFR 1915.56(b)(4): When welding cable became worn to the extent of exposing bare conductors, the portion exposed was not protected by means of rubber tape, friction tape, or other equivalent insulation.  Weather deck Shaver barge:  On or about May 27, 2015 and times prior thereto, welding cables were used that had cuts to the conductor.  This exposed employees to potential electric shock hazard if they contacted conductor while welding.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1915.158 A01

Other-than-serious 1 instance 1 exposed
Issued
Jul 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1915.158(a)(1): PFDs (life preservers, life jackets, or work vests) were not worn by each affected employee must be United States Coast Guard (USCG) approved pursuant to 46 CFR part 160 (Type I, II, III, or V PFD) and marked for use as a work vest, for commercial use, or for use on vessels. USCG approval is pursuant to 46 CFR part 160, Coast Guard Lifesaving Equipment Specifications.  Floating vessel:  On or about May 27, 2015 and times prior thereto, employee was not wearing a PFD while working next to the water.  This exposed employee to a potential fall into the water.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View JT Marine, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340664788.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.