BREWTON, AL —
OSHA Inspection: CASHEL BEAMS AND FLOORING, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CASHEL BEAMS AND FLOORING, LLC in 104 1ST AVE, BREWTON, AL 36426 (NAICS 321912). OSHA activity number 340669092.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CASHEL BEAMS AND FLOORING, LLC
- Site address
- 104 1ST AVE
- City
- BREWTON
- State
- AL
- ZIP
- 36426
- Mailing
- 104 1ST AVE, BREWTON, AL 36426
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321912
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 4, 2015
- Penalty
- Initial $1,360 · Current $1,191 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of being struck by fragments of Polyvinyl Chloride (PVC) plastic pipe in the event that the PVC plastic pipe ruptured: a)Wood processing area; On or about June 1, 2015 and at times prior, the employer exposed his employees to the hazard of being struck by fragments of Polyvinyl Chloride (PVC) plastic pipe in the event that the PVC plastic pipe ruptured. PVC plastic piping was used in exposed above ground locations to transport compressed air at 120 psi. The employer failed to follow ASME Gas Transmission and Distribution Piping Systems - ASME Code for Pressure Piping, B31. Section 842.3.3 Installation Provisions which prohibits the above ground use of PVC pipe for compressed air conveyance.
Recent events (2)
- — I (S) $1191
- — Z (S) $1360
1910.219 C02 I
- Issued
- Aug 4, 2015
- Penalty
- Initial $1,600 · Current $1,191 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) Unimart 23 machine; on June 4, 2015 and times prior the employer exposed employees to caught in and amputation hazards, where the 16 inch, red shaft that drives the exit belt, while removing boards from machine standing within 48 inches .
Recent events (2)
- — I (S) $1191
- — Z (S) $1600
1910.253 B02 II
- Issued
- Aug 4, 2015
- Penalty
- Initial $2,800 · Current $1,191 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: a) Loading dock area; on June 1, 2015 and times prior the employer exposed employees to explosion and struck by hazards due to allowing oxygen and acetylene gas cylinders to be stored unsecured by the loading dock door. The cylinders were in storage with regulators and hoses attached, but were not secured from falling over or being struck by, but not limited to, employees, forklift, or lumber.
Recent events (2)
- — I (S) $1191
- — Z (S) $2800
1910.253 B02 IV
- Issued
- Aug 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: a) Loading dock area; on June 1, 2015 and times prior the employer exposed employees to explosion and struck by hazards due to allowing oxygen and acetylene gas cylinders to be stored beside the loading dock door. The cylinders had the regulators and hoses attached instead of valve protection caps that protected the valves from damage due to falling over or being struck by, but not limited to, employees, forklift, or lumber.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.176 B
- Issued
- Aug 4, 2015
- Abate by
- Aug 12, 2015
- Penalty
- Initial $400 · Current $123 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: a)Warehouse and work area; on June1, 2015 and times prior the employer exposed employees to struck by hazards by allowing unstable stacks of lumber to be stacked near the forklift pathways.
Recent events (2)
- — I (O) $123
- — Z (O) $400
More inspections at Cashel Beams and Flooring, LLC
View Cashel Beams and Flooring, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321912)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340669092.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.