CANTON, OH —
OSHA Inspection: TIMKENSTEEL CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TIMKENSTEEL CORPORATION in 1835 DUEBER AVE SW, CANTON, OH 44706 (NAICS 331110). OSHA activity number 340676394.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TIMKENSTEEL CORPORATION
- Site address
- 1835 DUEBER AVE SW
- City
- CANTON
- State
- OH
- ZIP
- 44706
- Mailing
- 2401 FAIRCREST AVE. SW, CANTON, OH 44706
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331110
- Employees
- 350
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 19, 2015
- Penalty
- Initial $7,000 · Current $7,000
1900
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to an oxygen deficient atmosphere while performing servicing and maintenance activities within the South vacuum filter housing located downstream of the secondary baghouse in the Faircrest Steel Plant. On or about May 21, 2015, the employer failed to ensure that employees entering the South vacuum filter housing for the Dust Away System of the Secondary Baghouse to perform servicing and maintenance were protected from the hazards posed by an oxygen deficient atmosphere caused by the upstream introduction of nitrogen.
Recent events (3)
- — F (S) $7000
- — C (S) $7000
- — Z (S) $7000
1910.134 D01 I
- Issued
- Nov 19, 2015
- Penalty
- Initial $0 · Current $0
1900
General-duty citation text
29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability: On or about May 21, 2015, the employer failed to ensure the appropriate respirators were selected for employees entering the South Vacuum Blower for the Dust Away System to perform maintenance, in that, employees were wearing an N95 half-face respirator while in an oxygen deficient atmosphere.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Timkensteel Corporation
View Timkensteel Corporation's full OSHA safety record →
More inspections in this industry (NAICS 331110)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340676394.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.