Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TIMKENSTEEL CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TIMKENSTEEL CORPORATION in 1835 DUEBER AVE SW, CANTON, OH 44706 (NAICS 331110). OSHA activity number 340676394.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Timkensteel Corporation — free Get an email when a new federal OSHA severe-injury report for Timkensteel Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1835 DUEBER AVE SW
City
CANTON
State
OH
ZIP
44706
Mailing
2401 FAIRCREST AVE. SW, CANTON, OH 44706
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331110
Employees
350
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 5 exposed
Issued
Nov 19, 2015
Penalty
Initial $7,000 · Current $7,000

Hazardous substances 1900

OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to an oxygen deficient atmosphere while performing servicing and maintenance activities within the South vacuum filter housing located downstream of the secondary baghouse in the Faircrest Steel Plant.   On or about May 21, 2015, the employer failed to ensure that employees entering the South vacuum filter housing for the Dust Away System of the Secondary Baghouse to perform servicing and maintenance were protected from the hazards posed by an oxygen deficient atmosphere caused by the upstream introduction of nitrogen.
Recent events (3)
  • — F (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.134 D01 I

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Nov 19, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 1900

29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability:  On or about May 21, 2015, the employer failed to ensure the appropriate respirators were selected for employees entering the South Vacuum Blower for the Dust Away System to perform maintenance, in that, employees were wearing an N95 half-face respirator while in an oxygen deficient atmosphere.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View Timkensteel Corporation's full OSHA safety record →