OSHA Inspection: ASHLEY FURNITURE INDUSTRIES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ASHLEY FURNITURE INDUSTRIES, INC. in 447 HIGHWAY 346, ECRU, MS 38841 (NAICS 337121). OSHA activity number 340682541.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ashley Furniture Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Ashley Furniture Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
447 HIGHWAY 346
City
ECRU
State
MS
ZIP
38841
Mailing
P. O. BOX 368, ECRU, MS 38841
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337121
Employees
2500
Ownership type
A

8 citations on file for this inspection.

1910.24 H

Other-than-serious 2 instances 2 exposed
Issued
Nov 17, 2015
Penalty
Initial $4,400 · Current $5,750
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: Stair railings and handrails were not installed in accordance with the provisions of 1910.23(e).    (a) Facility - On or about June 01, 2015 the following open sided 5 rung stairways were missing midrails.              (i) WS004 Eagle - One rail on each stair side               (ii) VT-1 Glue Tote - One rail on eachh stair side
Recent events (3)
  • — F (O) $5750
  • — C (S) $4400
  • — Z (S) $4400

1910.132 F01 V

Other-than-serious 1 instance 6 exposed
Issued
Nov 17, 2015
Abate by
Dec 10, 2015
Penalty
Initial $2,550 · Current $5,750
29 CFR 1910.132(f)(1)(v): Employee(s) required to use PPE by this section were not trained to know the proper care, maintenance, useful life, and disposal of the PPE:    (a) Facility - On or about June 01, 2015  maintenance technicians and electricians were provided flame retardant (FR) clothing, arc rated hood w/ face shield, and O electrically insulating gloves without prior training on how to use and maintain the PPE.
Recent events (3)
  • — F (O) $5750
  • — C (S) $2550
  • — Z (S) $2550

1910.137 C02 VIII

Other-than-serious 1 instance 6 exposed
Issued
Nov 17, 2015
Abate by
Dec 10, 2015
Penalty
Initial $5,500 · Current $0 Reduced
29 CFR 1910.137(c)(2)(viii): 29 CFR 1910.137(c)(2)(viii): Electrical protective equipment was not subjected to periodic electrical tests in accordance with Tables I-4 and I-5:    (a) Facility - On or about June 01, 2015 maintenance technicians and electricians were provided Class O electrically insulating gloves that were not tested in accordance with Table I-5 which requires testing: Before first issue and every 6 months thereafter.
Recent events (3)
  • — F (O) $0
  • — C (S) $5500
  • — Z (S) $5500

1910.147 C04 II D

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 17, 2015
Abate by
Dec 10, 2015
Penalty
Initial $6,600 · Current $5,750 Reduced
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control.    (a) Facility - On or about June 01, 2015 the machine specific LOTO procedure did not contain a clear means of testing to ensure the pneumatic (air) was deleted prior to performing servicing or maintenance on the machine.        - WS138 Schelling Machine      - WB678 Vertical Bore      - WR185 Heian Router      - FV004 VT Machine
Recent events (3)
  • — F (S) $5750
  • — C (S) $6600
  • — Z (S) $6600

1910.303 B02

Other-than-serious 5 instances 6 exposed
Issued
Nov 17, 2015
Penalty
Initial $3,300 · Current $5,750
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing and labeling.    (a) Facility - On or about June 01, 2015 multi-outlet electric power strips (re-locatable power taps) were used to power high current electrical equipment such as industrial fans and portable banding machines.
Recent events (3)
  • — F (O) $5750
  • — C (S) $3300
  • — Z (S) $3300

1910.305 G01 IV A

Other-than-serious 3 instances 3 exposed
Issued
Nov 17, 2015
Abate by
Dec 17, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for permanent building wiring.      (a)  Facility - On or about June 01, 2015 flexible wiring was used to power fixed equipment.         - Heian routers  WR185, WR201       - Schelling saw conveyor
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.333 B02 II A

Other-than-serious 1 instance 1 exposed
Issued
Nov 17, 2015
Abate by
Dec 17, 2015
Penalty
Initial $3,300 · Current $0 Reduced
29 CFR 1910.333(b)(2)(ii)(A): Safe procedures for deenergizing circuits and equipment shall be determined before circuits or equipment are deenergized.    (a) Bagging area - On or about June 01, 2015 a project team electrician replaced a defective 110 volt electrical outlet without an established LOTO procedure.
Recent events (3)
  • — F (O) $0
  • — C (S) $3300
  • — Z (S) $3300

1910.333 C02

Other-than-serious 1 instance 3 exposed
Issued
Nov 17, 2015
Abate by
Dec 10, 2015
Penalty
Initial $5,500 · Current $0 Reduced
29 CFR 1910.333(c)(2): The employer did not ensure that only qualified persons were working on energized circuits and that qualified persons were familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools.    (a) Facility - On or about June 01, 2015 maintenance employees are allowed to use electrical test equipment and electrical rated PPE, such as arc flash hoods, Class 0 gloves, and FR clothing without being trained to safely use and maintain the equipment.
Recent events (3)
  • — F (O) $0
  • — C (S) $5500
  • — Z (S) $5500

View Ashley Furniture Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340682541.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.