Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STEELFAB, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STEELFAB, INC. in 902A SMITH STREET, DUBLIN, GA 31021 (NAICS 332312). OSHA activity number 340686039.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Steelfab, INC. — free Get an email when a new federal OSHA severe-injury report for Steelfab, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
STEELFAB, INC.
Site address
902A SMITH STREET
City
DUBLIN
State
GA
ZIP
31021
Mailing
902A SMITH STREET, DUBLIN, GA 31021
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
75
Ownership type
A

8 citations on file for this inspection.

1910.22 A01

Other-than-serious 1 instance 2 exposed
Issued
Nov 30, 2015
Abate by
Dec 10, 2015
Penalty
Initial $3,400 · Current $3,400
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.      A)    By Roller Bin, on or about June 4, 2015, employees walk and work by the blasting booth where the accumulation of the blasting agent (steel pellets) on the floor, exposed employees to a slip/fall hazard.
Recent events (2)
  • — I (O) $3400
  • — Z (S) $3400

1910.212 A01

Other-than-serious 1 instance 2 exposed
Issued
Nov 30, 2015
Penalty
Initial $4,250 · Current $2,869 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      A) Center area of detail shop, on or about June 4, 2015, the rear area of a mechanical shearing machine was not guarded to prevent employees from entering the area during operation, exposing employees to an amputation hazard.
Recent events (2)
  • — I (O) $2869
  • — Z (S) $4250

1910.253 B04 III

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 30, 2015
Penalty
Initial $3,400 · Current $2,550 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least 1/2 hour rating.      A)  Fab shop inside building, on or about June 4, 2015, oxygen cylinders were stored with LP gas bottles (fuel cylinders), exposing employees to a fire hazard.
Recent events (2)
  • — I (S) $2550
  • — Z (S) $3400

1910.253 E05 IV

Other-than-serious 1 instance 2 exposed
Issued
Nov 30, 2015
Penalty
Initial $3,400 · Current $2,550 Reduced
29 CFR 1910.253(e)(5)(iv): Hose connections were not clamped or otherwise securely fastened in a manner that would withstand, without leakage, twice the pressure to which they would normally be subjected in service, but in no case less than a pressure of 300 psi (2.04 MPa).       A) Fabrication shop by column B- 2, on or about June 5, 2015, an oxygen hose connected to an oxygen cylinder leaked oxygen when the hose was pressurized, exposing employees to a fire hazard.
Recent events (2)
  • — I (O) $2550
  • — Z (S) $3400

1910.253 E06 II

Other-than-serious 1 instance 2 exposed
Issued
Nov 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.253(e)(6)(ii): When regulators or parts of regulators, including gages, needed repair, the work was not performed by skilled mechanics who had been properly instructed:      A) Fab shop welding area, on or about June 4, 2015, an employee used a compressed gas cylinder that had a damaged gage on the regulator without the gage being repaired by a skilled mechanic, exposing employees to a fire hazard.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 5 2 instances 4 exposed
Issued
Nov 30, 2015
Penalty
Initial $3,400 · Current $2,550 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):     A)  By column B2 fab shop, on or about June 4, 2015, electrical extension cords with damaged outer and inner insulation of the electrical wires, were not inspected before use, exposing employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $2550
  • — Z (S) $3400

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
Nov 30, 2015
Abate by
Dec 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  A) Production areas, on or about June 16, 2015, the employer did not perform a periodic review of the lockout/tag out program for equipment such as, the duplicating machine and shearing machine.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.254 D09 III

Other-than-serious 2 instances 2 exposed
Issued
Nov 30, 2015
Abate by
Dec 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replace:    A)  Throughout shop, or about June 5, 2015, employee used welding cables that had damaged outer insulation that had been repaired with electrical tape, exposing employees to a minor electrical shock hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Steelfab, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340686039.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.