BAY MINETTE, AL —
OSHA Inspection: FULTON HALEY METAL PRODUCTS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FULTON HALEY METAL PRODUCTS, INC. in 41360 PINE GROVE ROAD, BAY MINETTE, AL 36507 (NAICS 332322). OSHA activity number 340687276.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FULTON HALEY METAL PRODUCTS, INC.
- Site address
- 41360 PINE GROVE ROAD
- City
- BAY MINETTE
- State
- AL
- ZIP
- 36507
- Mailing
- 41360 PINE GROVE ROAD, BAY MINETTE, AL 36507
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 15
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.303 B01 IV
- Issued
- Oct 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1)(iv): Electric equipment was not free from the recognized hazard of damaged insulation: a) Shop; On or about June 3, 2015 and at times prior thereto, the employer permitted employees to use the foot pedal of the HTC Hydra-Tool shear that had damaged insulation on its cord and had been repaired with electrical tape. b) Shop; On or about June 3, 2015 and at times prior thereto, the employer permitted employees to use the foot pedal of the Pacific press break that had damaged insulation on its cord where bare wiring was present.
Recent events (1)
- — Z (O) $0
1910.305 G02 III
- Issued
- Oct 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Shop; On or about June 3, 2015 and at times prior thereto, the employer permitted employees to use the foot pedal of the Pacific brand press break whose power cord was not provided with strain relief.
Recent events (1)
- — Z (O) $0
More inspections at Fulton Haley Metal Products, INC.