Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CENTRE CONCRETE COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CENTRE CONCRETE COMPANY in 2280 EAST COLLEGE AVENUE, STATE COLLEGE, PA 16801 (NAICS 327320). OSHA activity number 340688233.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Centre Concrete Company — free Get an email when a new federal OSHA severe-injury report for Centre Concrete Company is published. One employer, no account, unsubscribe in one click.
Site address
2280 EAST COLLEGE AVENUE
City
STATE COLLEGE
State
PA
ZIP
16801
Mailing
2280 EAST COLLEGE AVE, STATE COLLEGE, PA 16801
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
100
Ownership type
A

12 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $3,500 · Current $2,275 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toe-boards:  a) Crow's Nest - Employees checking the pressure relief valve in the crow's nest of the silo are exposed to a fifteen (15) foot fall hazard. The employer has not provided the protection of a guard rail or equivalent device, on or about June 4th, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.  Note:  Toe-boards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.
Recent events (2)
  • — I (S) $2275
  • — Z (S) $3500

1910.23 D01 III

Serious Gravity 1 2 instances 10 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $2,100 · Current $1,365 Reduced
29 CFR 1910.23(d)(1)(iii): Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side:  a)  Upper Garage Staircase Right - Employees using the right staircase to the upper garage are exposed to a trip and fall hazard from the staircase with only one handrail and no mid-rail, on or about June 4th, 2015.  b)  Upper Garage Staircase Left - Employees using the left staircase to the upper garage are exposed to a trip and fall hazard from the staircase with only one handrail and no mid-rail, on or about June 4th, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1365
  • — Z (S) $2100

1910.23 E01

Serious Gravity 1 3 instances 30 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level:  a) Staircase To Chemical Room - Employees using the staircase to the chemical room are exposed to a trip and fall hazard from the staircase not having a mid-rail, on or about June 4th, 2015.  b) Upper Garage Staircase Right - Employees using the right staircase to the upper garage are exposed to a trip and fall hazard from the staircase not having a mid-rail, on or about June 4th, 2015.  c)  Upper Garage Staircase Left - Employees using the left staircase to the upper garage are exposed to a trip and fall hazard from the staircase not having a mid-rail, on or about June 4th, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.27 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $3,500 · Current $2,275 Reduced
29 CFR 1910.27(b)(1)(ii): The distance between rungs exceeded 12 inches and were not uniform throughout the ladder:  a) Access Catwalk - Employees climbing the sixty-four and a half (64.5) inch fixed ladder were exposed to slip hazards from the distance between rungs exceeding 12 inches, on or about June 04, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2275
  • — Z (S) $3500

1910.27 B01 III

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.27(b)(1)(iii): The minimum clear length of rungs or cleats was not 16 inches:  a) Access Catwalk - Employees climbing the sixty-four and a half (64.5) inch fixed ladder were exposed to slip hazards from the length of rungs or cleats measuring fourteen and a half (14.5) inches from outside to outside, on or about June 04, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.27 C04

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.27(c)(4): The employer did not install fixed ladders with at least 7 inches of clearance from the centerline of the rung to the nearest permanent object in the back of the ladder:  a) Access Catwalk - Employees climbing the sixty-four and a half (64.5) inch fixed ladder were exposed to slip hazards from rungs that were less than 7 inches to the nearest permanent object, on or about June 04, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.27 C06

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.27(c)(6): "Step-across distance." The step-across distance from the nearest edge of ladder to the nearest edge of equipment or structure was more than 12 inches, or less than 2 1/2 inches:   a) Access Catwalk - Employees climbing the sixty-four and a half (64.5) inch fixed ladder were exposed to slip hazards from the top rung not having a step distance of greater than two and a half (2.5) or less than twelve (12) inches to the nearest edge of the wall, on or about June 04, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.36 G02

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 10, 2015
Abate by
Feb 15, 2016
Penalty
Initial $3,500 · Current $2,275 Reduced
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  a) Batch Drum - Employees working in the tower near the Batch Drum are exposed to fire hazards from exit routes less than 28 inches wide at all points, on or about June 4th, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2275
  • — Z (S) $3500

1910.157 G01

Other-than-serious 1 instance 100 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $2,100 · Current $1,365 Reduced
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire-fighting:    a) Centre Concrete - The employer did not provide an educational program to familiarize employees with the proper use of fire extinguishers for incipient stage fire-fighting, on or about June 4th, 2015.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.    Note:  Applies where all employees are expected to fight fires.
Recent events (2)
  • — I (O) $1365
  • — Z (S) $2100

1910.184 D

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $2,100 · Current $1,365 Reduced
29 CFR 1910.184(d): Damaged or defective sling(s) were not immediately removed from service:  a) Block Chain - The employer did not ensure that the approximate ten (10) foot alloy steel chain sling was taken out of service.  The hook was worn and did not have a load rating tag exposing employees to a struck-by hazard from an overloaded chain, on or about June 4th, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1365
  • — Z (S) $2100

1910.184 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach:  a) Block Chain - The employer did not ensure that the approximate ten (10) foot alloy steel chain sling was properly identified with size, grade, rated capacity, and reach exposing employees to a struck-by hazard from an overloaded chain, on or about June 4th, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 10, 2015
Abate by
Oct 6, 2015
Penalty
Initial $4,900 · Current $3,185 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Crow's Nest - Employees working in the crow's nest next to the conveyor were exposed to a nip point where the conveyor belt went over the roller, on or about June 4th, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $3185
  • — Z (S) $4900

View Centre Concrete Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340688233.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.