STATE COLLEGE, PA —
OSHA Inspection: CENTRE CONCRETE COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CENTRE CONCRETE COMPANY in 123 HAWBAKER INDUSTRIAL DRIVE, STATE COLLEGE, PA 16803 (NAICS 327320). OSHA activity number 348201898.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CENTRE CONCRETE COMPANY
- Site address
- 123 HAWBAKER INDUSTRIAL DRIVE
- City
- STATE COLLEGE
- State
- PA
- ZIP
- 16803
- Mailing
- 629 EAST ROLLING RIDGE DRIVE, BELLEFONTE, PA 16823
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327320
- Employees
- 7
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C07 III B
- Issued
- Aug 14, 2025
- Abate by
- Oct 1, 2025
- Penalty
- Initial $5,296 · Current $10,000
General-duty citation text
1910.147(c)(7)(iii)(B) Additional retraining was not provided whenever a periodic inspection under 29 CFR 1910.147(c)(6) revealed that there were deviations from or inadequacies in the employee's knowledge or use of the energy control procedures: a) 123 Hawbaker Industrial Drive, State College - Conveyor Belt "Deadman Pulley" - On or about April 24, 2025, the employer did not conduct an annual or more frequent inspection of the energy control procedures utilized in the control of hazardous energy. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $10000
- — Z (S) $5296
1910.147 C06 I C
- Issued
- Aug 14, 2025
- Abate by
- Oct 1, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. a) 123 Hawbaker Industrial Drive, State College - Conveyor Belt "Deadman Pulley" - On or about April 24, 2025, the employer did not conduct an annual or more frequent audit of authorized employees utilizing the energy control procedures. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D02
- Issued
- Aug 14, 2025
- Abate by
- Oct 1, 2025
- Penalty
- Initial $5,296 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(2):The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) 123 Hawbaker Industrial Drive, State College - Conveyor Belt "Deadman Pulley" - On or about April 24, 2025, an employee was exposed to nip -point hazards while cleaning a conveyor roller when the employee did not applied a personal lock to the energy source of the conveyor belt before performing service and maintenance on the conveyor belt system. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $5296
More inspections at Centre Concrete Company
View Centre Concrete Company's full OSHA safety record →
More inspections in this industry (NAICS 327320)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348201898.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.