BILLINGS, MT —
OSHA Inspection: HCL TRUCK & EQUIPMENT
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HCL TRUCK & EQUIPMENT in 233 ORCHARD LANE, BILLINGS, MT 59101 (NAICS 336211). OSHA activity number 340695931.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HCL TRUCK & EQUIPMENT
- Site address
- 233 ORCHARD LANE
- City
- BILLINGS
- State
- MT
- ZIP
- 59101
- Mailing
- 233 ORCHARD LANE, BILLINGS, MT 59101
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336211
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.106 E06 II
- Issued
- Nov 9, 2015
- Abate by
- Dec 7, 2015
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire: (a) Spray booth: On or about June 08, 2015, and at times prior, employees were exposed to fire and explosion hazards from flammable liquids such as but not limited to, Lacquer Thinner (Flash point -4 DEG F), Tufcote (Flash point 83 DEG F), OMNI MR 186 (Flash point 24 DEG F), when these flammable liquids were transferred without grounding and bonding. (b) Prep room: On or about June 08, 2015, and at times prior, employees were exposed to fire and explosion hazards from flammable liquids such as but not limited to, Lacquer Thinner (Flash point -4 DEG F), Tufcote (Flash point 83 DEG F), OMNI MR 186 (Flash point 24 DEG F), when flammable liquids were transferred without grounding and bonding.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.107 C06
- Issued
- Nov 9, 2015
- Abate by
- Dec 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations: (a) Spray booth: On or about June 08, 2015 and at times prior, employees were exposed to fire and explosion hazards when non explosion proof flexible extension cords were used in the spray booth to energize electrical equipment. (b) Spray booth: On or about June 08, 2015 and at times prior, employees were exposed to fire and explosion hazards when a non explosion proof radio was used in the spray booth. (c) Spray booth: On or about June 08, 2015 and at times prior, employees were exposed to fire and explosion hazards when non explosion lights were used. (d) Spray booth: On or about June 08, 2015 and at times prior, employees were exposed to fire and explosion hazards when non explosion proof outlets were used in the spray booth.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 E02
- Issued
- Nov 9, 2015
- Abate by
- Dec 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids were kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift: (a) Spray booth: On or about June 08, 2015, and at times prior, employees were exposed to fire and explosion hazards from flammable liquids such as but not limited to, Lacquer Thinner (Flash point -4 DEG F), Tufcote (Flash point 83 DEG F), OMNI MR 186 (Flash point 24 DEG F), when excessive amounts were stored in close proximity of spraying operations. (b) Prep room: On or about June 08, 2015, and at times prior, employees were exposed to fire and explosion hazards from flammable liquids such as but not limited to, Lacquer Thinner (Flash point -4 DEG F), Tufcote (Flash point 83 DEG F), OMNI MR 186 (Flash point 24 DEG F), when excessive amounts were stored in close proximity of spraying operations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Nov 9, 2015
- Abate by
- Dec 7, 2015
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer shall establish and implement a written respiratory protection program with worksite-specific procedures. The program shall be updated as necessary to reflect those changes in workplace conditions that affect respirator use: (a) Spray booth: On or about June 08, 2015 and at times prior, employees were exposed to respiratory hazards while using 3M 5300 negative pressure, half face piece respirators in spray painting applications (b) Abrasive blasting area: On or about June 08, 2015 and at times prior, employees were exposed to respiratory hazards while using a Bullard supplied air respirator during abrasive blasting operations.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.134 I05 IV
- Issued
- Nov 9, 2015
- Abate by
- Dec 7, 2015
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.134(i)(5)(iv): The employer did not ensure that the person authorized to perform the necessary sorbent bed and filter changes filled out a tag indicating by the signature and date that maintenance changes were performed: (a) Abrasive blasting area: On or about June 08, 2015 and at times prior, employees were exposed to respiratory hazards while using an unmaintained Bullard supplied air respirator during abrasive blasting operations.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.134 I07
- Issued
- Nov 9, 2015
- Abate by
- Dec 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both: (a) Abrasive blasting area: On or about June 08, 2015 and at times prior, employees were exposed to carbon monoxide while using a Bullard supplied air respirator during abrasive blasting operations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 I08
- Issued
- Nov 9, 2015
- Abate by
- Dec 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(8): Breathing air couplings were not incompatible with other gas systems to prevent inadvertent servicing of air line respirators with non-respirable gases or oxygen: (a) Abrasive blasting area: On or about June 08, 2015 and at times prior, employees were exposed to respiratory hazards while using a Bullard supplied air respirator during abrasive blasting operations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at HCL Truck & Equipment
View HCL Truck & Equipment's full OSHA safety record →
More inspections in this industry (NAICS 336211)
More inspections in MT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340695931.