LANCASTER, NY —
OSHA Inspection: MOLDTECH, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of MOLDTECH, INC. in 1900 COMMERCE PARKWAY, LANCASTER, NY 14086 (NAICS 326112). OSHA activity number 340696863.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOLDTECH, INC.
- Site address
- 1900 COMMERCE PARKWAY
- City
- LANCASTER
- State
- NY
- ZIP
- 14086
- Mailing
- 1900 COMMERCE PARKWAY, LANCASTER, NY 14086
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326112
- Employees
- 69
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.106 E02 II A
- Issued
- Oct 22, 2015
- Abate by
- May 21, 2016
- Penalty
- Initial $2,975 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(ii)(a): Except as provided in subdivisions (b) and (c) of this subdivision, all storage did not comply with paragraph (d) (3) or (4) of this section: 29 CFR 1910.106(d)(3)(ii): Fire resistance. Storage cabinets were not designed and constructed to limit the internal temperature to not more than 325 degrees F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969 which is incorporated by reference as specified in 1910.6. All joints and seams must remain tight and the door must remain securely closed during the fire test. Cabinets must be labeled in conspicuous lettering, "Flammable -- Keep Fire Away." a) Insert Prep, paint booth 1 - On or about 8/5/15, the 55 gallon drum of methyl ethyl ketone, a Category 1 flammable liquid with a flash point of 16 degrees F, was stored in an non-approved Justrite combustible liquid storage cabinet. This cabinet was stored on the second level of a rack and a hose and wire were inserted through the bottom vent bung. b) Insert Prep, paint booth 1 - On or about 8/5/15, the 55 gallon drum of toluene, a Category 2 flammable liquid with a flash point of 39.2 degrees F, was stored in an non-approved Justrite combustible liquid storage cabinet. The cabinet was stored on the second level of a rack and a hose and wire were inserted through a gasket hole in the cabinet wall. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $1100
- — C (S) $2975
- — Z (S) $2975
1910.106 E02 IV D
- Issued
- Oct 22, 2015
- Abate by
- May 21, 2016
- Penalty
- Initial $2,975 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve: a) Insert Prep, paint booth 1 - On or about 8/5/15, the 55 gallon drum of methyl ethyl ketone, a Category 1 flammable liquid with a flash point of 16 degrees F, was gravity fed through a fitting with an open ball valve. b) Insert Prep, paint booth 1 - On or about 8/5/15, the 55 gallon drum of toluene, a Category 2 flammable liquid with a flash point of 39.2 degrees F, was gravity fed through a fitting with an open ball valve. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $1100
- — C (S) $2975
- — Z (S) $2975
1910.107 E02
- Issued
- Oct 22, 2015
- Abate by
- May 21, 2016
- Penalty
- Initial $2,975 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.107(e)(2): Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) kept in the vicinity of spraying operations should be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) must be in a separate, constructed building detached from other important buildings or cut off in a standard manner. a) Insert Prep, paint booth 1 - On or about 8/5/15, the 55 gallon drum of methyl ethyl ketone, a Category 1 flammable liquid with a flash point of 16 degrees F, kept in the vicinity of spraying operations exceeded a supply of 1 day or one shift. b) Insert Prep, paint booth 1 - On or about 8/5/15, the 55 gallon drum of toluene, a Category 2 flammable liquid with a flash point of 39.2 degrees F, kept in the vicinity of spraying operations exceeded a supply of 1 day or one shift. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $1100
- — C (S) $2975
- — Z (S) $2975
1910.138 A
- Issued
- Oct 22, 2015
- Abate by
- May 21, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes. (a) Insert Prep, work table - On or about 6/11/15, an employees' hands were exposed to the hazard of skin absorption of methyl ethyl ketone when cleaning parts. The Protective Industrial Products 100% nylon knit gloves with the nitrile NBR palm coat deteriorated when in contact with methyl ethyl ketone. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Moldtech, INC.
View Moldtech, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326112)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340696863.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.