PAGO PAGO, AS —
OSHA Inspection: SAMOA MOTORS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of SAMOA MOTORS, INC. in 1120 TAFUNA INDUSTRIAL PARK, PAGO PAGO, AS 96799 (NAICS 811121). OSHA activity number 340698430.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAMOA MOTORS, INC.
- Site address
- 1120 TAFUNA INDUSTRIAL PARK
- City
- PAGO PAGO
- State
- AS
- ZIP
- 96799
- Mailing
- P.O. BOX 1120, PAGO PAGO, AS 96799
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 11
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.22 A01
- Issued
- Jul 31, 2015
- Abate by
- Aug 12, 2015
- Penalty
- Initial $1,020 · Current $714 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. a. On May 29, 2015, the transmission overhaul bay and tool room were not maintained in an orderly manner as the floor was cluttered with auto assembly parts, exposing employees to a tripping hazard.
Recent events (2)
- — I (S) $714
- — Z (S) $1020
1910.303 G01 II
- Issued
- Jul 31, 2015
- Abate by
- Aug 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a. On May 29, 2015, at the north wall of the main shop the electrical control panel for the lights and automobile lift compressor was blocked by an engine, arc welding unit and empty drums.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 E02
- Issued
- Jul 31, 2015
- Abate by
- Aug 12, 2015
- Penalty
- Initial $1,020 · Current $714 Reduced
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly. a. On May 29, 2015, fire extinguishers in the automobile shop were not inspected on a monthly basis.
Recent events (2)
- — I (S) $714
- — Z (S) $1020
1910.157 E03
- Issued
- Jul 31, 2015
- Abate by
- Aug 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a. On May 29, 2015, fire extinguishers in the automobile shop were not inspected on an annual basis.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 G02
- Issued
- Jul 31, 2015
- Abate by
- Aug 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a. On May 29, 2015, employees expected to use fire extinguishers in the event of a fire were not trained on the general principles of a fire extinguisher use and the hazards involved with incipient stage fire fighting.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.141 D02 IV
- Issued
- Jul 31, 2015
- Abate by
- Aug 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(d)(2)(iv): Lavatories were not provided with individual hand towels or sections thereof, of cloth or paper, warm air blowers or clean individual sections of continuous cloth toweling: a. On May 29, 2015, men's restroom was not provided with clean individual hand towels, cloth or paper towels to use after using the restroom.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.304 G05
- Issued
- Jul 31, 2015
- Abate by
- Aug 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a. On May 29, 2015, the ground prong on the extension cord used to power a portable drill was missing, exposing employees to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Samoa Motors, INC.
View Samoa Motors, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811121)
More inspections in AS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340698430.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.