OSHA Inspection: JEN JAC'S RESTORATIONS, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JEN JAC'S RESTORATIONS, INC in 2789 US HWY 80, GARDEN CITY, GA 31408 (NAICS 336413). OSHA activity number 340706480.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JEN Jac'S Restorations, INC — free Get an email when a new federal OSHA severe-injury report for JEN Jac'S Restorations, INC is published. One employer, no account, unsubscribe in one click.
Site address
2789 US HWY 80
City
GARDEN CITY
State
GA
ZIP
31408
Mailing
2789 US HWY 80, GARDEN CITY, GA 31408
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336413
Employees
45
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 3, 2015
Abate by
Dec 8, 2015
Penalty
Initial $2,800 · Current $1,680 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:    a) At the facility, on or about June 11, 2015, the employer did not furnish the employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to being struck-by or punctured by high velocity projectiles during the rupture of polyvinyl chloride (PVC) pipe with a line pressure of 90 pounds per square inch (psi) being used to transport compressed air to operate the CNC Mill Machines, air sanders, drill motors, etc.  The piping was not approved for use with compressed air.  Fragmentation of the pipe can occur because of fatigue caused by cold contents and/or vibrations or the compressed shifting position and placing additional stress on the PVC pipe connector.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 3, 2015
Abate by
Dec 8, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     a)  At the facility, on or about June 11, 2015, the Jet drop band saw did not have the unused portion of the blade guarded, exposing employees to an amputation hazard.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.213 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 3, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:     a)  At the facility, on or about June 11, 2015, an employee was using a Powermatic Table Saw without the guard for the portion of the saw blade above the table, thus exposing the employee to amputation hazards.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.242 B

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 3, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a) At the facility,  on or about June 11, 2015 and at times prior to, employees were using compressed air, greater than 90 psi to clean off the machine and parts, exposing employees to eye injuries.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 3, 2015
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:     a) At the facility,  on or about June 11, 2015 and at times prior to, a 220 volts electrical receptacle outlet box designed to be mounted was being used as a pendant to power a miller welder, thus exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100